Synergistic Effect of Tungstate and Benzotriazole on Corrosion Inhibition of Carbon Steel in Solutions Containing Cl
Fang Li
Abstract
Fang Li
Abstract
The corrosion inhibition of tungstate, benzotriazole (BTA) and their combination in solutions containing Cl- was studied by electrochemical techniques. The results indicated that the inhibition efficiency of tungstate was higher than that of BTA. The efficiency increased with increasing concentration of tungstate or BTA. In the studies of synergistic effect of tungstate and BTA, it had been found that in pH 9.0 solution, the largest R t could be obtained with the concentration ratio of tungstate / BTA being 1∶1. Lowering the pH value of solution would reduce the efficiency of inhibitors, especially in binary inhibitors. Increasing the concentration of Cl- accelerated the corrosion of carbon steel in the solutions with various inhibitors, but the influence of Cl- on corroding rate in binary inhibitors was not so strong as in single component. The results of surface analysis showed that W, C, N, O and Fe elements existed in the protecting film formed with binary inhibitors. The thickness of the film was about 1215 nm.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The corrosion inhibition of tungstate, benzotriazole (BTA) and their combination in solutions containing Cl- was studied by electrochemical techniques. The results indicated that the inhibition efficiency of tungstate was higher than that of BTA. The efficiency increased with increasing concentration of tungstate or BTA. In the studies of synergistic effect of tungstate and BTA, it had been found that in pH 9.0 solution, the largest R t could be obtained with the concentration ratio of tungstate / BTA being 1∶1. Lowering the pH value of solution would reduce the efficiency of inhibitors, especially in binary inhibitors. Increasing the concentration of Cl- accelerated the corrosion of carbon steel in the solutions with various inhibitors, but the influence of Cl- on corroding rate in binary inhibitors was not so strong as in single component. The results of surface analysis showed that W, C, N, O and Fe elements existed in the protecting film formed with binary inhibitors. The thickness of the film was about 1215 nm.
Key concepts: Tungstate, Benzotriazole, Corrosion, Electrochemistry, Carbon steel, Sodium tungstate, Inorganic chemistry, Chemistry