2010Chinese Journal of Health Laboratory TechnologyRequires access

Microwave digestion-atomic fluorescence determination of selenium

Changhong Zhang

Open publisher page 0 citations

Abstract

Objective:To establish a microwave digestion and Atomic Fluorescence Determination of Se.Methods: Of microwave digestion of water samples digestion treatment,Atomic Fluorescence Determination of selenium content.Results: Of full and complete digestion,recovery of 95.7%~104.7%,and the method detection limit was 0.12 μg/L,in 0.001 μg/ml~0.10 μg/ml range,correlation coefficient r=0.9997,the relative standard deviation of 1.5%.Conclusion: Microwave digestion of water samples,the digestive process saving agents,to prevent the loss of elements in samples tested,less interference for the determination of selenium in water.

About this research paper

What this paper is about

Objective:To establish a microwave digestion and Atomic Fluorescence Determination of Se.Methods: Of microwave digestion of water samples digestion treatment,Atomic Fluorescence Determination of selenium content.Results: Of full and complete digestion,recovery of 95.7%~104.7%,and the method detection limit was 0.12 μg/L,in 0.001 μg/ml~0.10 μg/ml range,correlation coefficient r=0.9997,the relative standard deviation of 1.5%.Conclusion: Microwave digestion of water samples,the digestive process saving agents,to prevent the loss of elements in samples tested,less interference for the determination of selenium in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a microwave digestion and Atomic Fluorescence Determination of Se.Methods: Of microwave digestion of water samples digestion treatment,Atomic Fluorescence Determination of selenium content.Results: Of full and complete digestion,recovery of 95.7%~104.7%,and the method detection limit was 0.12 μg/L,in 0.001 μg/ml~0.10 μg/ml range,correlation coefficient r=0.9997,the relative standard deviation of 1.5%.Conclusion: Microwave digestion of water samples,the digestive process saving agents,to prevent the loss of elements in samples tested,less interference for the determination of selenium in water.

Key concepts: Microwave digestion, Digestion (alchemy), Selenium, Chemistry, Detection limit, Fluorescence, Microwave, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Microwave digestion-atomic fluorescence determination of selenium — Research Paper | ScholarLens