2001•Zhonghua chuangshang guke zazhiRequires access

Biomechanical Evaluation and Clinical Application Report of Various Forms of Modified Tension Band Wiring for Patellar Fracture

Xu X

Open publisher page 0 citations

Abstract

Objective The study was conducted to provide experimental relevant data of internal fixation method for patallar fracture clinically. Methods Using cadaver extremitis with the quadriceps tendon-patellar tendon and intact capsular apparatus, the tibia and femur were mounted in an Instron Materials Testing System , and the tibiofemoral joint was held at 36° of flexion. Tension was applied to the patellar through the quadriceps tendon and fracture displacement was measured with linear motion transducers. Displacement of 3mm was considered to represent failure of fixation. AO tension band wiring, Xu's tension band wiring, figure of eight tension band wiring and Magnusson wiring were examined respectively. Results The figure of eight and Xu's tension band wiring were more effective than AO tension band wiring. All of them could bear tensive force over 294N and may provide sufficient fixation to allow immediate range of motion after operation. Magnusson wiring could bear force less than 294N, which appeared not firm enough. Accordingly, 42 cases of patellar fracture were treated with figure of eight tension band wiring, the excellent and good results was 95. 2% at follow-up studies ranged from 6 to 26 months. Conclusion Figure of eight tension band wiring should be selected firstly in the treatment of fracture of patellar for its effective fixation.

About this research paper

What this paper is about

Objective The study was conducted to provide experimental relevant data of internal fixation method for patallar fracture clinically. Methods Using cadaver extremitis with the quadriceps tendon-patellar tendon and intact capsular apparatus, the tibia and femur were mounted in an Instron Materials Testing System , and the tibiofemoral joint was held at 36° of flexion. Tension was applied to the patellar through the quadriceps tendon and fracture displacement was measured with linear motion transducers. Displacement of 3mm was considered to represent failure of fixation. AO tension band wiring, Xu's tension band wiring, figure of eight tension band wiring and Magnusson wiring were examined respectively. Results The figure of eight and Xu's tension band wiring were more effective than AO tension band wiring. All of them could bear tensive force over 294N and may provide sufficient fixation to allow immediate range of motion after operation. Magnusson wiring could bear force less than 294N, which appeared not firm enough. Accordingly, 42 cases of patellar fracture were treated with figure of eight tension band wiring, the excellent and good results was 95. 2% at follow-up studies ranged from 6 to 26 months. Conclusion Figure of eight tension band wiring should be selected firstly in the treatment of fracture of patellar for its effective fixation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective The study was conducted to provide experimental relevant data of internal fixation method for patallar fracture clinically. Methods Using cadaver extremitis with the quadriceps tendon-patellar tendon and intact capsular apparatus, the tibia and femur were mounted in an Instron Materials Testing System , and the tibiofemoral joint was held at 36° of flexion. Tension was applied to the patellar through the quadriceps tendon and fracture displacement was measured with linear motion transducers. Displacement of 3mm was considered to represent failure of fixation. AO tension band wiring, Xu's tension band wiring, figure of eight tension band wiring and Magnusson wiring were examined respectively. Results The figure of eight and Xu's tension band wiring were more effective than AO tension band wiring. All of them could bear tensive force over 294N and may provide sufficient fixation to allow immediate range of motion after operation. Magnusson wiring could bear force less than 294N, which appeared not firm enough. Accordingly, 42 cases of patellar fracture were treated with figure of eight tension band wiring, the excellent and good results was 95. 2% at follow-up studies ranged from 6 to 26 months. Conclusion Figure of eight tension band wiring should be selected firstly in the treatment of fracture of patellar for its effective fixation.

Key concepts: Tension band wiring, Patella fracture, Fixation (population genetics), Medicine, Patellar tendon, Orthodontics, Tension (geology), Displacement (psychology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Biomechanical Evaluation and Clinical Application Report of Various Forms of Modified Tension Band Wiring for Patellar Fracture — Research Paper | ScholarLens