2012•Insulators and Surge ArrestersRequires access

Research of Lightning Overvoltage Protection Program for Traction Transformer Substation of Passenger Dedicated Railway Line

Jing Chen

Open publisher page 1 citations

Abstract

The lightning overvoltage protection program for enter line side and feeder side of 220 kV traction transformer substation of passenger dedicated railway line were researched.The lightning overvoltage simulation model of the traction transformer substation was established with ATP-EMTP,and the various lightning arrester setting methods were simulated and analyzed.The optimal arrester setting method was selected through simulation,that is for the enter line side a group of arrester respectively set in both sides of cross connection and in front of transformer,or feeder side,a group of arrester was respectively set in the joint of cable with over head contact line and in the GIS switch cabinet.

About this research paper

What this paper is about

The lightning overvoltage protection program for enter line side and feeder side of 220 kV traction transformer substation of passenger dedicated railway line were researched.The lightning overvoltage simulation model of the traction transformer substation was established with ATP-EMTP,and the various lightning arrester setting methods were simulated and analyzed.The optimal arrester setting method was selected through simulation,that is for the enter line side a group of arrester respectively set in both sides of cross connection and in front of transformer,or feeder side,a group of arrester was respectively set in the joint of cable with over head contact line and in the GIS switch cabinet.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The lightning overvoltage protection program for enter line side and feeder side of 220 kV traction transformer substation of passenger dedicated railway line were researched.The lightning overvoltage simulation model of the traction transformer substation was established with ATP-EMTP,and the various lightning arrester setting methods were simulated and analyzed.The optimal arrester setting method was selected through simulation,that is for the enter line side a group of arrester respectively set in both sides of cross connection and in front of transformer,or feeder side,a group of arrester was respectively set in the joint of cable with over head contact line and in the GIS switch cabinet.

Key concepts: Lightning arrester, Transformer, Overvoltage, Surge arrester, Engineering, Emtp, Electrical engineering, Traction substation

Related papers

Back to paper searchBrowse research topicsOriginal source
Research of Lightning Overvoltage Protection Program for Traction Transformer Substation of Passenger Dedicated Railway Line — Research Paper | ScholarLens