Detection of Cr( III) and Cr( VI) in capsule with spectrophotometry
Chen Si-ha
Abstract
Chen Si-ha
Abstract
Objective To develop a new determination method of valence and content of chromium in capsule by spectrophotometry. Methods Capsule was dealt with dry ashing method. Chromium( Ⅲ) was oxidized into chromium( Ⅵ) by ammonium persulfate. The resulting chromium( Ⅵ) can react with diphenylcarbazide to form a purple water- soluble complex,which was determined by spectrophotometry. And the experimental conditions was optimized by single factor method. Results The maximum absorption wavelength of the complex was 540 nm. The linear range of the proposed method was 0. 01 μg / ml ~0. 16 μg / ml. The regression equation was y = 1. 414x- 0. 00127 with a detection limit of 0. 01 μg / ml. The correlation coefficient was 0. 9998. The molar absorptivity for Cr( Ⅵ) was 7. 3 × 104 L /( mol·cm). Relative standard deviation were respectively 4. 3%,3. 6% and 2. 7%,and the spiked recoveries were respectively 98. 6%,100. 4% and 102. 3%. Conclusion The proposed method is simple,sensitive and rapid,and the detection results are satisfactory.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To develop a new determination method of valence and content of chromium in capsule by spectrophotometry. Methods Capsule was dealt with dry ashing method. Chromium( Ⅲ) was oxidized into chromium( Ⅵ) by ammonium persulfate. The resulting chromium( Ⅵ) can react with diphenylcarbazide to form a purple water- soluble complex,which was determined by spectrophotometry. And the experimental conditions was optimized by single factor method. Results The maximum absorption wavelength of the complex was 540 nm. The linear range of the proposed method was 0. 01 μg / ml ~0. 16 μg / ml. The regression equation was y = 1. 414x- 0. 00127 with a detection limit of 0. 01 μg / ml. The correlation coefficient was 0. 9998. The molar absorptivity for Cr( Ⅵ) was 7. 3 × 104 L /( mol·cm). Relative standard deviation were respectively 4. 3%,3. 6% and 2. 7%,and the spiked recoveries were respectively 98. 6%,100. 4% and 102. 3%. Conclusion The proposed method is simple,sensitive and rapid,and the detection results are satisfactory.
Key concepts: Molar absorptivity, Spectrophotometry, Chromium, Chemistry, Detection limit, Ammonium persulfate, Analytical Chemistry (journal), Ashing