2013Zhongguo shiyan fangjixue zazhiRequires access

Determination on Content of Paeonol and Paeoniflorin in Guizhi Fuling Pills from Different Pharmaceutical Factories by HPLC

Kang Yan-lei

Open publisher page 1 citations

Abstract

Objective:To establish a determination method of paeonol and paeoniflorin content in GFW and to compare its content discrepancy in GFW from different pharmaceutical factories.Method: HPLC was used to simultaneously determine the content of paeonol and paeoniflorin.An Elite Hypersil BDS C18(4.6 mm×250 mm,5 μm) column was used for content determination.The mobile phase was acetonitrile-0.1% phosphoric acid aqueous solution.Flow rate was 1.0 mL·min-1.The detection wavelength was set at 230 nm(0-17 min)→274 nm(17-26 min).The injection volume was 20 μL and column temperature was maintained at 30 ℃.Result: The linear range of paeonol was 2.02-22.40 μg(r=0.999 9);the linear range of paeoniflorin was 2.40-20.26 μg(r=0.999 9).The average recovery was 99.5%,99.4%,and RSD was 0.96%,0.81%(n=9) respectively.Conclusion: The established chromatographic method which had good repeatability can be used to determine the content of paeonol and paeoniflorin in GFW simply and accurately and can be used to evaluate the quality of GFW from different pharmaceutical factories.

About this research paper

What this paper is about

Objective:To establish a determination method of paeonol and paeoniflorin content in GFW and to compare its content discrepancy in GFW from different pharmaceutical factories.Method: HPLC was used to simultaneously determine the content of paeonol and paeoniflorin.An Elite Hypersil BDS C18(4.6 mm×250 mm,5 μm) column was used for content determination.The mobile phase was acetonitrile-0.1% phosphoric acid aqueous solution.Flow rate was 1.0 mL·min-1.The detection wavelength was set at 230 nm(0-17 min)→274 nm(17-26 min).The injection volume was 20 μL and column temperature was maintained at 30 ℃.Result: The linear range of paeonol was 2.02-22.40 μg(r=0.999 9);the linear range of paeoniflorin was 2.40-20.26 μg(r=0.999 9).The average recovery was 99.5%,99.4%,and RSD was 0.96%,0.81%(n=9) respectively.Conclusion: The established chromatographic method which had good repeatability can be used to determine the content of paeonol and paeoniflorin in GFW simply and accurately and can be used to evaluate the quality of GFW from different pharmaceutical factories.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a determination method of paeonol and paeoniflorin content in GFW and to compare its content discrepancy in GFW from different pharmaceutical factories.Method: HPLC was used to simultaneously determine the content of paeonol and paeoniflorin.An Elite Hypersil BDS C18(4.6 mm×250 mm,5 μm) column was used for content determination.The mobile phase was acetonitrile-0.1% phosphoric acid aqueous solution.Flow rate was 1.0 mL·min-1.The detection wavelength was set at 230 nm(0-17 min)→274 nm(17-26 min).The injection volume was 20 μL and column temperature was maintained at 30 ℃.Result: The linear range of paeonol was 2.02-22.40 μg(r=0.999 9);the linear range of paeoniflorin was 2.40-20.26 μg(r=0.999 9).The average recovery was 99.5%,99.4%,and RSD was 0.96%,0.81%(n=9) respectively.Conclusion: The established chromatographic method which had good repeatability can be used to determine the content of paeonol and paeoniflorin in GFW simply and accurately and can be used to evaluate the quality of GFW from different pharmaceutical factories.

Key concepts: Paeoniflorin, Paeonol, Chromatography, Chemistry, Repeatability, Phosphoric acid, High-performance liquid chromatography, Content determination

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination on Content of Paeonol and Paeoniflorin in Guizhi Fuling Pills from Different Pharmaceutical Factories by HPLC — Research Paper | ScholarLens