2011Zhongguo shiyan fangjixue zazhiRequires access

Determination of Paeoniflorin,Geniposide and Paeonol in Chaishao Pills by HPLC

Zheng Hui

Open publisher page 0 citations

Abstract

Objective:To establish an HPLC method for the simultaneous determination of paeoniflorin,geniposide and paeonol in Chaishao Pills.Method: Paeoniflorin,geniposide and paeonol were separated on Inertsil ODS-SP(4.6 mm×150 mm,5 μm) column and detected at 230 nm.The mobile phase was acetonitrile-water with gradient elution.The flow rate was 1.0 mL·min-1.Result: Paeoniflorin,geniposide and paeonol were linear within the range of 0.494 4-12.36 μg(r=1),0.492 2-12.305 μg(r=0.999 9) and 0.260 2-6.505 μg,(r=0.999 9) respectively.The average recovery was 98.77%(2.1%),101.64%(1.9%) and 100.92%(1.7%).Conclusion: The method is simple,reproducible,and it can be used for the quality control of Chaishao pills.

About this research paper

What this paper is about

Objective:To establish an HPLC method for the simultaneous determination of paeoniflorin,geniposide and paeonol in Chaishao Pills.Method: Paeoniflorin,geniposide and paeonol were separated on Inertsil ODS-SP(4.6 mm×150 mm,5 μm) column and detected at 230 nm.The mobile phase was acetonitrile-water with gradient elution.The flow rate was 1.0 mL·min-1.Result: Paeoniflorin,geniposide and paeonol were linear within the range of 0.494 4-12.36 μg(r=1),0.492 2-12.305 μg(r=0.999 9) and 0.260 2-6.505 μg,(r=0.999 9) respectively.The average recovery was 98.77%(2.1%),101.64%(1.9%) and 100.92%(1.7%).Conclusion: The method is simple,reproducible,and it can be used for the quality control of Chaishao pills.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish an HPLC method for the simultaneous determination of paeoniflorin,geniposide and paeonol in Chaishao Pills.Method: Paeoniflorin,geniposide and paeonol were separated on Inertsil ODS-SP(4.6 mm×150 mm,5 μm) column and detected at 230 nm.The mobile phase was acetonitrile-water with gradient elution.The flow rate was 1.0 mL·min-1.Result: Paeoniflorin,geniposide and paeonol were linear within the range of 0.494 4-12.36 μg(r=1),0.492 2-12.305 μg(r=0.999 9) and 0.260 2-6.505 μg,(r=0.999 9) respectively.The average recovery was 98.77%(2.1%),101.64%(1.9%) and 100.92%(1.7%).Conclusion: The method is simple,reproducible,and it can be used for the quality control of Chaishao pills.

Key concepts: Paeoniflorin, Paeonol, Chromatography, Chemistry, High-performance liquid chromatography, Gradient elution, Linear range, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Paeoniflorin,Geniposide and Paeonol in Chaishao Pills by HPLC — Research Paper | ScholarLens