2009Journal of Yibin UniversityRequires access

Determination of Matrine,5-Hydroxymethylfurfural and Related Substances in Injection Containing Matrine and Glucose by HPLC

Yang Shan-bin

Open publisher page 0 citations

Abstract

Objecttive,to study the determination of matrine,5-hydroxymethyfurfural,and related substances in matrine and glucose injection.Methods: the high-performance liquid chromatography(HPLC) method was carried out according to the Chinese Pharmacopoeia,3 batch of samples were determined under the condition: amino-bonded silica as the column,acetonitrile-0.02mol/L NaH2PO4 solution(75∶25) as the mobile phase,the detection wavelength was 210nm and the theoretical plates were more than 5000 calculated by matrine.Results,the calibration curve was linear in the range of 21.966~109.83μg/ml(r = 0.999 9).The mean recovery was 100.43 %,RSD was 2.02 %(n = 9),the determination of 5-Hydroxymethylfurfural and related substances also have good results.Conclusion,this method is sensitive,accurate and reproducible,can be used for quality control of matrine and glucose Injection.

About this research paper

What this paper is about

Objecttive,to study the determination of matrine,5-hydroxymethyfurfural,and related substances in matrine and glucose injection.Methods: the high-performance liquid chromatography(HPLC) method was carried out according to the Chinese Pharmacopoeia,3 batch of samples were determined under the condition: amino-bonded silica as the column,acetonitrile-0.02mol/L NaH2PO4 solution(75∶25) as the mobile phase,the detection wavelength was 210nm and the theoretical plates were more than 5000 calculated by matrine.Results,the calibration curve was linear in the range of 21.966~109.83μg/ml(r = 0.999 9).The mean recovery was 100.43 %,RSD was 2.02 %(n = 9),the determination of 5-Hydroxymethylfurfural and related substances also have good results.Conclusion,this method is sensitive,accurate and reproducible,can be used for quality control of matrine and glucose Injection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objecttive,to study the determination of matrine,5-hydroxymethyfurfural,and related substances in matrine and glucose injection.Methods: the high-performance liquid chromatography(HPLC) method was carried out according to the Chinese Pharmacopoeia,3 batch of samples were determined under the condition: amino-bonded silica as the column,acetonitrile-0.02mol/L NaH2PO4 solution(75∶25) as the mobile phase,the detection wavelength was 210nm and the theoretical plates were more than 5000 calculated by matrine.Results,the calibration curve was linear in the range of 21.966~109.83μg/ml(r = 0.999 9).The mean recovery was 100.43 %,RSD was 2.02 %(n = 9),the determination of 5-Hydroxymethylfurfural and related substances also have good results.Conclusion,this method is sensitive,accurate and reproducible,can be used for quality control of matrine and glucose Injection.

Key concepts: Matrine, Chromatography, Chemistry, High-performance liquid chromatography, Calibration curve, Acetonitrile, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Matrine,5-Hydroxymethylfurfural and Related Substances in Injection Containing Matrine and Glucose by HPLC — Research Paper | ScholarLens