2012The Journal of Clinical AnesthesiologyRequires access

Comparison of I-gel laryngeal mask and common laryngeal mask in breast surgery undergoing general anesthesia

Liao Zi-we

Open publisher page 0 citations

Abstract

Objective To compare the application of the I-gel laryngeal mask and the common laryngeal mask in breast surgery with general anesthesia.Methods Sixty patients,ASA I or II,undergoing the breast surgery with general anesthesia were randomized into two groups:I-gel group (group I) and common group (group S).Achievement ratio of first time insertion,inserting time,airway sealing pressure,classification after bronchoscopy of fiberoptic bronchoscope,wake time and extubation time were recorded.HR,BP,SpO2,PETCO2 and peak airway pressure (Ppeak) were monitored 15,30,45 and 60 min after insertion.The complications were also recorded.Results Compared with group S,achievement ratio(76% vs 90%),airway sealing pressure [(23.8±4.5)cm H2O vs (27.6±4.7) cm H2O] and classification were better and the inserting time [(26.5±8.3)s vs (15.2±2.6)s] were shorter in group I (P0.05).There was no significant difference in wake time,extubation time,and HR,BP,SpO2 and Ppeak and complications in both groups.Conclusion Application of the I-gel laryngeal mask in airway management during breast surgery with general anesthesia is better than the common laryngeal mask.

About this research paper

What this paper is about

Objective To compare the application of the I-gel laryngeal mask and the common laryngeal mask in breast surgery with general anesthesia.Methods Sixty patients,ASA I or II,undergoing the breast surgery with general anesthesia were randomized into two groups:I-gel group (group I) and common group (group S).Achievement ratio of first time insertion,inserting time,airway sealing pressure,classification after bronchoscopy of fiberoptic bronchoscope,wake time and extubation time were recorded.HR,BP,SpO2,PETCO2 and peak airway pressure (Ppeak) were monitored 15,30,45 and 60 min after insertion.The complications were also recorded.Results Compared with group S,achievement ratio(76% vs 90%),airway sealing pressure [(23.8±4.5)cm H2O vs (27.6±4.7) cm H2O] and classification were better and the inserting time [(26.5±8.3)s vs (15.2±2.6)s] were shorter in group I (P0.05).There was no significant difference in wake time,extubation time,and HR,BP,SpO2 and Ppeak and complications in both groups.Conclusion Application of the I-gel laryngeal mask in airway management during breast surgery with general anesthesia is better than the common laryngeal mask.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To compare the application of the I-gel laryngeal mask and the common laryngeal mask in breast surgery with general anesthesia.Methods Sixty patients,ASA I or II,undergoing the breast surgery with general anesthesia were randomized into two groups:I-gel group (group I) and common group (group S).Achievement ratio of first time insertion,inserting time,airway sealing pressure,classification after bronchoscopy of fiberoptic bronchoscope,wake time and extubation time were recorded.HR,BP,SpO2,PETCO2 and peak airway pressure (Ppeak) were monitored 15,30,45 and 60 min after insertion.The complications were also recorded.Results Compared with group S,achievement ratio(76% vs 90%),airway sealing pressure [(23.8±4.5)cm H2O vs (27.6±4.7) cm H2O] and classification were better and the inserting time [(26.5±8.3)s vs (15.2±2.6)s] were shorter in group I (P0.05).There was no significant difference in wake time,extubation time,and HR,BP,SpO2 and Ppeak and complications in both groups.Conclusion Application of the I-gel laryngeal mask in airway management during breast surgery with general anesthesia is better than the common laryngeal mask.

Key concepts: Medicine, Laryngeal mask airway, Anesthesia, Airway, Laryngeal Masks, Bronchoscopy, Breast surgery, Airway management

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of I-gel laryngeal mask and common laryngeal mask in breast surgery undergoing general anesthesia — Research Paper | ScholarLens