2007Journal of Xi'an University of Engineering Science and TechnologyRequires access

Experimental study on the performance for the dew point indirect evaporative cooler

Yongmei Xuan

Open publisher page 1 citations

Abstract

The data analysis of dew point indirect evaporative cooler is carried out. The results show that the dew point cooler can make the outlet dry-bulb temperature under the inlet wet-bulb temperature.When the inlet wet-bulb temperature is fixed,with the increase of inlet dry-bulb temperature,outlet dry-bulb temperature and difference in temperature increace,the efficiency would decrease.When the inlet dry-bulb temperature is fixed,with the increase of inlet wet-bulb temperature,the outlet dry-bulb temperature increase,difference in temperature and efficiency decreace,with the inlet rehumidity increasing,the outlet dry-bulb temperature increase.The optimum wind value of primary and secondary rate is about 1.5.

About this research paper

What this paper is about

The data analysis of dew point indirect evaporative cooler is carried out. The results show that the dew point cooler can make the outlet dry-bulb temperature under the inlet wet-bulb temperature.When the inlet wet-bulb temperature is fixed,with the increase of inlet dry-bulb temperature,outlet dry-bulb temperature and difference in temperature increace,the efficiency would decrease.When the inlet dry-bulb temperature is fixed,with the increase of inlet wet-bulb temperature,the outlet dry-bulb temperature increase,difference in temperature and efficiency decreace,with the inlet rehumidity increasing,the outlet dry-bulb temperature increase.The optimum wind value of primary and secondary rate is about 1.5.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The data analysis of dew point indirect evaporative cooler is carried out. The results show that the dew point cooler can make the outlet dry-bulb temperature under the inlet wet-bulb temperature.When the inlet wet-bulb temperature is fixed,with the increase of inlet dry-bulb temperature,outlet dry-bulb temperature and difference in temperature increace,the efficiency would decrease.When the inlet dry-bulb temperature is fixed,with the increase of inlet wet-bulb temperature,the outlet dry-bulb temperature increase,difference in temperature and efficiency decreace,with the inlet rehumidity increasing,the outlet dry-bulb temperature increase.The optimum wind value of primary and secondary rate is about 1.5.

Key concepts: Dew point, Inlet, Dry-bulb temperature, Wet-bulb temperature, Bulb, Evaporative cooler, Dew, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental study on the performance for the dew point indirect evaporative cooler — Research Paper | ScholarLens