Determination of camphor in camphor cream by Κ-ratio method
Xiaohong Zhou
Abstract
Xiaohong Zhou
Abstract
Objective:To establish a determination method of camphor in camphor cream.Methods:With the wavelength of 289 nm and 294 nm as the determinable points,the signal multiplier method was used.Results:The detector response was linear in the range of 0.5-2.5 mg/ml(r=0.999 8) for camphor.The average recovery was 100.6%,RSD=1.05%(n=5).Conclusion:The method is accurate and simple,reliable convinient and stable.It can be used for quality control of camphor cream.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To establish a determination method of camphor in camphor cream.Methods:With the wavelength of 289 nm and 294 nm as the determinable points,the signal multiplier method was used.Results:The detector response was linear in the range of 0.5-2.5 mg/ml(r=0.999 8) for camphor.The average recovery was 100.6%,RSD=1.05%(n=5).Conclusion:The method is accurate and simple,reliable convinient and stable.It can be used for quality control of camphor cream.
Key concepts: Camphor, Medicine, Linear relationship, Linear range, Chromatography, Traditional medicine, Statistics, Mathematics