2009Fluid MachineryRequires access

Influence of the Air/Water Ratio and the Cross-section Velocity on Cooling Efficiency in Spraying Cooling Tower

Chen Huang

Open publisher page 0 citations

Abstract

According to the principle of atomization cooling,a 80t/h experimental counter-flow no-padding spraying cooling tower was established.And through four experimental conditions the influence of the air/water ratio and the cross-section velocity on cooling efficiency in spraying cooling tower was analyzed.The results showed: the cooling efficiency would increase when the air/water ratio and the cross-section velocity increased,for example when the cross-section velocity changed from 1.93m/s to 3.21m/s,meanwhile the air/water ratio changed from 1.04 to 1.31,and the cooling efficiency would change from 39.0% to 54.5% consequently;if the air/water ratio remained unchanged or had a smaller change from 1.16 to 1.20,the cooling efficiency of the cooling tower could be improved by the way of increasing the cross-section velocity.

About this research paper

What this paper is about

According to the principle of atomization cooling,a 80t/h experimental counter-flow no-padding spraying cooling tower was established.And through four experimental conditions the influence of the air/water ratio and the cross-section velocity on cooling efficiency in spraying cooling tower was analyzed.The results showed: the cooling efficiency would increase when the air/water ratio and the cross-section velocity increased,for example when the cross-section velocity changed from 1.93m/s to 3.21m/s,meanwhile the air/water ratio changed from 1.04 to 1.31,and the cooling efficiency would change from 39.0% to 54.5% consequently;if the air/water ratio remained unchanged or had a smaller change from 1.16 to 1.20,the cooling efficiency of the cooling tower could be improved by the way of increasing the cross-section velocity.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

According to the principle of atomization cooling,a 80t/h experimental counter-flow no-padding spraying cooling tower was established.And through four experimental conditions the influence of the air/water ratio and the cross-section velocity on cooling efficiency in spraying cooling tower was analyzed.The results showed: the cooling efficiency would increase when the air/water ratio and the cross-section velocity increased,for example when the cross-section velocity changed from 1.93m/s to 3.21m/s,meanwhile the air/water ratio changed from 1.04 to 1.31,and the cooling efficiency would change from 39.0% to 54.5% consequently;if the air/water ratio remained unchanged or had a smaller change from 1.16 to 1.20,the cooling efficiency of the cooling tower could be improved by the way of increasing the cross-section velocity.

Key concepts: Cooling tower, Cross section (physics), Mechanics, Water cooling, Tower, Chiller, Free cooling, Meteorology