Experimental Research on the Effect of Cross-Wind to Wet-Cooling Tower Performance

Qing Yang Wang, Tian Yu Sun, Jian Zhang, Jian Ren

Open full text 0 citations

Abstract

Environmental cross-wind has a influence on cooling capacity of wet cooling tower to a great extent in power plant.The variation of circulating-water temperature difference (Δt) and cooling coefficient of efficiency(η) with cross-wind velocity, circulating water inlet temperature and flow rate, are shown under cross-wind conditions, compared with cases without wind. By using experimental platform of cooling water system based on 300MW thermal power unit,it is found that with cross-wind velocity increasing,cooling temperature difference and cooling efficiency decrease first then increase at the knee point when the velocity value is 0.8m/s. In addition, the correlation betweenΔt ,η and parameters,such as circulating-water inlet temperature and flow rate, is derived for cases with windless conditions.

About this research paper

What this paper is about

Environmental cross-wind has a influence on cooling capacity of wet cooling tower to a great extent in power plant.The variation of circulating-water temperature difference (Δt) and cooling coefficient of efficiency(η) with cross-wind velocity, circulating water inlet temperature and flow rate, are shown under cross-wind conditions, compared with cases without wind. By using experimental platform of cooling water system based on 300MW thermal power unit,it is found that with cross-wind velocity increasing,cooling temperature difference and cooling efficiency decrease first then increase at the knee point when the velocity value is 0.8m/s. In addition, the correlation betweenΔt ,η and parameters,such as circulating-water inlet temperature and flow rate, is derived for cases with windless conditions.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Environmental cross-wind has a influence on cooling capacity of wet cooling tower to a great extent in power plant.The variation of circulating-water temperature difference (Δt) and cooling coefficient of efficiency(η) with cross-wind velocity, circulating water inlet temperature and flow rate, are shown under cross-wind conditions, compared with cases without wind. By using experimental platform of cooling water system based on 300MW thermal power unit,it is found that with cross-wind velocity increasing,cooling temperature difference and cooling efficiency decrease first then increase at the knee point when the velocity value is 0.8m/s. In addition, the correlation betweenΔt ,η and parameters,such as circulating-water inlet temperature and flow rate, is derived for cases with windless conditions.

Key concepts: Cooling tower, Wind speed, Inlet, Environmental science, Water cooling, Flow (mathematics), Tower, Mechanics