2009•Journal of Hainan Normal UniversityRequires access

Determination of Residual Organic Solvents in Cefetamet by Capillary Gas Chromatography with Headspace Sampling

Zhenyi Liang

Open publisher page 0 citations

Abstract

Headspace gas chromatography method was used for the determination of four kinds of residual organic solvents in cefetamet. The samples were injected into DB-624capillary column by headspace sampler and analyzed with FID detector. The linear ranges of ethanol, acetone ,dichloromethane and tetrahydro furan were 0.2-7.0 mg·mL-1 (r=0.9995),0.2-7.0 mg·mL-1 (r=0.9994) ,0.03-1.0 mg·mL-1 (r=0.9993) and 0.02-0.9 mg·mL-1 (r=0.9994) respectively. The recoveries were 100.5 %,99.6 %,99.0 % and 98.4 % with RSD 1.2 %,2.3 %,1.8 % and 2.8 %(n=5) respectively. The method is simple, accurate and sensitive with good reproducibility. It can be used for the determination of the residual organic solvents in cefetamet.

About this research paper

What this paper is about

Headspace gas chromatography method was used for the determination of four kinds of residual organic solvents in cefetamet. The samples were injected into DB-624capillary column by headspace sampler and analyzed with FID detector. The linear ranges of ethanol, acetone ,dichloromethane and tetrahydro furan were 0.2-7.0 mg·mL-1 (r=0.9995),0.2-7.0 mg·mL-1 (r=0.9994) ,0.03-1.0 mg·mL-1 (r=0.9993) and 0.02-0.9 mg·mL-1 (r=0.9994) respectively. The recoveries were 100.5 %,99.6 %,99.0 % and 98.4 % with RSD 1.2 %,2.3 %,1.8 % and 2.8 %(n=5) respectively. The method is simple, accurate and sensitive with good reproducibility. It can be used for the determination of the residual organic solvents in cefetamet.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Headspace gas chromatography method was used for the determination of four kinds of residual organic solvents in cefetamet. The samples were injected into DB-624capillary column by headspace sampler and analyzed with FID detector. The linear ranges of ethanol, acetone ,dichloromethane and tetrahydro furan were 0.2-7.0 mg·mL-1 (r=0.9995),0.2-7.0 mg·mL-1 (r=0.9994) ,0.03-1.0 mg·mL-1 (r=0.9993) and 0.02-0.9 mg·mL-1 (r=0.9994) respectively. The recoveries were 100.5 %,99.6 %,99.0 % and 98.4 % with RSD 1.2 %,2.3 %,1.8 % and 2.8 %(n=5) respectively. The method is simple, accurate and sensitive with good reproducibility. It can be used for the determination of the residual organic solvents in cefetamet.

Key concepts: Dichloromethane, Chromatography, Chemistry, Gas chromatography, Acetone, Residual, Detection limit, Capillary gas chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Residual Organic Solvents in Cefetamet by Capillary Gas Chromatography with Headspace Sampling — Research Paper | ScholarLens