2008•Geriatrics & Health CareRequires access

Correlation between CGMSBG and SMBG in different settings of measurement

Xiaoya Zhang

Open publisher page 0 citations

Abstract

Objective To evaluate the correlation between MiniMed continuous glucose monitoring system blood glucose(CGMSBG)and self monitoring blood glucose(SMBG)detected at different blood sugar levels and different time points to see whether there is any correlation between them.Methods 130 patients with type 2 diabetes admitted to this hospital were submitted to CGMS.The correlation and coincidence between CGMSBG and SMBG values at different blood sugar levels and different time points were assessed by Person correlation analysis.Results 1.The correlation coefficient r of 1609 CGMSBG values and paired SMBG values was 0.929(P=0.0001).When the age was below 70 years,the correlation coefficient r was 0.901(P=0.0001).When it was between70 and 80,the correlation coefficient r was 0.932(P=0.0001).When it was above 80,the correlation coefficient r was 0.875(P=0.0001).2.When SMBG value was below 4.4 mmol/L,the correlation coefficient r was 0.286(P=0.025).When it was between 4.4 and 10 mmol/L,the correlation coefficient r was 0.825(P=0.0001).When it was above 10 mmol/L,the correlation coefficient r was 0.838(P=0.0001).3.At 1~6h,7~12h,13~24h,25~48h and 49~72h after the installation of CGMS,the correlation coefficient r of CGMSBG values and SMBG values was 0.802,0.904,0.954,0.949 and 0.926 respectively.Conclusions 1.The correlation and coincidence between SMBG values and CGMSBG values are not affected by age.2.At different blood glucose levels,the correlation and coincidence between SMBG and CGMSBG values are favorable.The SMBG value and the CGMSBG value are most comparable when they are at the moderate level.3.At different time points of measurement,SMBG values and paired CGMSBG values are well correlated,especially at 25~48h.

About this research paper

What this paper is about

Objective To evaluate the correlation between MiniMed continuous glucose monitoring system blood glucose(CGMSBG)and self monitoring blood glucose(SMBG)detected at different blood sugar levels and different time points to see whether there is any correlation between them.Methods 130 patients with type 2 diabetes admitted to this hospital were submitted to CGMS.The correlation and coincidence between CGMSBG and SMBG values at different blood sugar levels and different time points were assessed by Person correlation analysis.Results 1.The correlation coefficient r of 1609 CGMSBG values and paired SMBG values was 0.929(P=0.0001).When the age was below 70 years,the correlation coefficient r was 0.901(P=0.0001).When it was between70 and 80,the correlation coefficient r was 0.932(P=0.0001).When it was above 80,the correlation coefficient r was 0.875(P=0.0001).2.When SMBG value was below 4.4 mmol/L,the correlation coefficient r was 0.286(P=0.025).When it was between 4.4 and 10 mmol/L,the correlation coefficient r was 0.825(P=0.0001).When it was above 10 mmol/L,the correlation coefficient r was 0.838(P=0.0001).3.At 1~6h,7~12h,13~24h,25~48h and 49~72h after the installation of CGMS,the correlation coefficient r of CGMSBG values and SMBG values was 0.802,0.904,0.954,0.949 and 0.926 respectively.Conclusions 1.The correlation and coincidence between SMBG values and CGMSBG values are not affected by age.2.At different blood glucose levels,the correlation and coincidence between SMBG and CGMSBG values are favorable.The SMBG value and the CGMSBG value are most comparable when they are at the moderate level.3.At different time points of measurement,SMBG values and paired CGMSBG values are well correlated,especially at 25~48h.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the correlation between MiniMed continuous glucose monitoring system blood glucose(CGMSBG)and self monitoring blood glucose(SMBG)detected at different blood sugar levels and different time points to see whether there is any correlation between them.Methods 130 patients with type 2 diabetes admitted to this hospital were submitted to CGMS.The correlation and coincidence between CGMSBG and SMBG values at different blood sugar levels and different time points were assessed by Person correlation analysis.Results 1.The correlation coefficient r of 1609 CGMSBG values and paired SMBG values was 0.929(P=0.0001).When the age was below 70 years,the correlation coefficient r was 0.901(P=0.0001).When it was between70 and 80,the correlation coefficient r was 0.932(P=0.0001).When it was above 80,the correlation coefficient r was 0.875(P=0.0001).2.When SMBG value was below 4.4 mmol/L,the correlation coefficient r was 0.286(P=0.025).When it was between 4.4 and 10 mmol/L,the correlation coefficient r was 0.825(P=0.0001).When it was above 10 mmol/L,the correlation coefficient r was 0.838(P=0.0001).3.At 1~6h,7~12h,13~24h,25~48h and 49~72h after the installation of CGMS,the correlation coefficient r of CGMSBG values and SMBG values was 0.802,0.904,0.954,0.949 and 0.926 respectively.Conclusions 1.The correlation and coincidence between SMBG values and CGMSBG values are not affected by age.2.At different blood glucose levels,the correlation and coincidence between SMBG and CGMSBG values are favorable.The SMBG value and the CGMSBG value are most comparable when they are at the moderate level.3.At different time points of measurement,SMBG values and paired CGMSBG values are well correlated,especially at 25~48h.

Key concepts: Correlation coefficient, Correlation, Coefficient of variation, Medicine, Pearson product-moment correlation coefficient, Positive correlation, Concordance correlation coefficient, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Correlation between CGMSBG and SMBG in different settings of measurement — Research Paper | ScholarLens