2013•Shaanxi Electric PowerRequires access

Study on Fault Component Differential Protection for Isolated Power System

Dan Hu

Open publisher page 0 citations

Abstract

For the space restriction in isolated power system,the cable is respectively short.To each level cable.the short current to the beginning and end of line is approximately equal over relay.The traditional time current principle can't satisfied the effective protection.By using longitudinal differential protection method,the generators parallel connection system is simulated in PSCAD/ EMTDC and the differential current protection is experimented in MATLAB.The research shows that the fault component differential protection has good ability against transient resistance,which also can distinguish internal and external faults effectively,satisfy the requirements of the elements(line and bus) effective protection.

About this research paper

What this paper is about

For the space restriction in isolated power system,the cable is respectively short.To each level cable.the short current to the beginning and end of line is approximately equal over relay.The traditional time current principle can't satisfied the effective protection.By using longitudinal differential protection method,the generators parallel connection system is simulated in PSCAD/ EMTDC and the differential current protection is experimented in MATLAB.The research shows that the fault component differential protection has good ability against transient resistance,which also can distinguish internal and external faults effectively,satisfy the requirements of the elements(line and bus) effective protection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

For the space restriction in isolated power system,the cable is respectively short.To each level cable.the short current to the beginning and end of line is approximately equal over relay.The traditional time current principle can't satisfied the effective protection.By using longitudinal differential protection method,the generators parallel connection system is simulated in PSCAD/ EMTDC and the differential current protection is experimented in MATLAB.The research shows that the fault component differential protection has good ability against transient resistance,which also can distinguish internal and external faults effectively,satisfy the requirements of the elements(line and bus) effective protection.

Key concepts: Differential protection, Transient (computer programming), Relay, Protective relay, Power-system protection, Fault (geology), MATLAB, Differential (mechanical device)

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on Fault Component Differential Protection for Isolated Power System — Research Paper | ScholarLens