This paper introduces the causes of line fault and expounds traveling wave protection and the criterion of protection action. Then establishes the simulation model of HVDC transmission system based on PSCAD/EMTDC, by which the line fault under different transition resistance and fault distance are simulated. Combined with the actual configuration and setting value of the line protection to analyze, the results show that the sensitivity of the terminal grounding fault caused by the one side protection input become poor. Therefore, it is proved that the two station configuration protection mode chosen in this project is suitable for operational settings of line protection, and the line protection can be operated correctly in the event of a fault. The simulation results also verify the reliability of the line protection setting and provide technical support for the operation of the line protection.

About this research paper

What this paper is about

This paper introduces the causes of line fault and expounds traveling wave protection and the criterion of protection action. Then establishes the simulation model of HVDC transmission system based on PSCAD/EMTDC, by which the line fault under different transition resistance and fault distance are simulated. Combined with the actual configuration and setting value of the line protection to analyze, the results show that the sensitivity of the terminal grounding fault caused by the one side protection input become poor. Therefore, it is proved that the two station configuration protection mode chosen in this project is suitable for operational settings of line protection, and the line protection can be operated correctly in the event of a fault. The simulation results also verify the reliability of the line protection setting and provide technical support for the operation of the line protection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper introduces the causes of line fault and expounds traveling wave protection and the criterion of protection action. Then establishes the simulation model of HVDC transmission system based on PSCAD/EMTDC, by which the line fault under different transition resistance and fault distance are simulated. Combined with the actual configuration and setting value of the line protection to analyze, the results show that the sensitivity of the terminal grounding fault caused by the one side protection input become poor. Therefore, it is proved that the two station configuration protection mode chosen in this project is suitable for operational settings of line protection, and the line protection can be operated correctly in the event of a fault. The simulation results also verify the reliability of the line protection setting and provide technical support for the operation of the line protection.

Key concepts: Fault (geology), Line (geometry), Reliability engineering, Ground, Reliability (semiconductor), Transmission line, Power-system protection, Electric power transmission

Related papers

Back to paper searchBrowse research topicsOriginal source
The simulation study on line protection of HVDC transmission system — Research Paper | ScholarLens