2006•Lishizhen Medicine and Materia Medica ResearchRequires access

Determination of Baicalin in Crude Baicalin by HPLC

Xin Nie, Luo Jia-bo, Xue-feng Xing

Open publisher page 0 citations

Abstract

ObjectiveTo establish an HPLC method for determination of baicalin in crude baicalin.MethodsUsing Agilent ZORBAX SB-C18 column(5 μm,4.6 mm×250 mm).The mobile phases consisted of methanol-water-acetic acid(49∶51∶(0.2)).The UV detector at 275 nm.ResultsThe average recoveries of baicalin were 101.64% and RSD were 1.75%(n=5).There is a good linearity in range of 0.102~1.020 μg of baicalin(r=0.999 7).ConclusionThe method is simple,accurate and can be used to determine the contents of baicalin and crude baicalin.

About this research paper

What this paper is about

ObjectiveTo establish an HPLC method for determination of baicalin in crude baicalin.MethodsUsing Agilent ZORBAX SB-C18 column(5 μm,4.6 mm×250 mm).The mobile phases consisted of methanol-water-acetic acid(49∶51∶(0.2)).The UV detector at 275 nm.ResultsThe average recoveries of baicalin were 101.64% and RSD were 1.75%(n=5).There is a good linearity in range of 0.102~1.020 μg of baicalin(r=0.999 7).ConclusionThe method is simple,accurate and can be used to determine the contents of baicalin and crude baicalin.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

ObjectiveTo establish an HPLC method for determination of baicalin in crude baicalin.MethodsUsing Agilent ZORBAX SB-C18 column(5 μm,4.6 mm×250 mm).The mobile phases consisted of methanol-water-acetic acid(49∶51∶(0.2)).The UV detector at 275 nm.ResultsThe average recoveries of baicalin were 101.64% and RSD were 1.75%(n=5).There is a good linearity in range of 0.102~1.020 μg of baicalin(r=0.999 7).ConclusionThe method is simple,accurate and can be used to determine the contents of baicalin and crude baicalin.

Key concepts: Baicalin, Chromatography, High-performance liquid chromatography, Chemistry, Acetic acid, Biochemistry