2012•Guangdong nongye kexueOpen access

Study on pesticide residues analysis in paddy soil,rice straw and grain

Qian Li

Open full text 0 citations

Abstract

A GC-MS method for determination of 12 pesticide residues in rice straw,paddy soil and grain was developed.The pesticides in samples was extracted with acetonitrile and cleaned up with florisil column,and then detected by gas chromatography-mass spectrometry.The calibration curves for 10 pesticide residues all had good linear relationships with correlation coefficients not less than 0.998.The spiked recoveries at three concentrations of 0.05,0.10,1.0 mg/L were ranged from 90.5% to 101.2 with relative standard deviations of 2.1%~4.7%.The limits of detection were in the range of 0.005~0.015 mg/L.It was an effective method which fit for the pesticide residues analysis and has high accuracy,precision and sensitivity.

About this research paper

What this paper is about

A GC-MS method for determination of 12 pesticide residues in rice straw,paddy soil and grain was developed.The pesticides in samples was extracted with acetonitrile and cleaned up with florisil column,and then detected by gas chromatography-mass spectrometry.The calibration curves for 10 pesticide residues all had good linear relationships with correlation coefficients not less than 0.998.The spiked recoveries at three concentrations of 0.05,0.10,1.0 mg/L were ranged from 90.5% to 101.2 with relative standard deviations of 2.1%~4.7%.The limits of detection were in the range of 0.005~0.015 mg/L.It was an effective method which fit for the pesticide residues analysis and has high accuracy,precision and sensitivity.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A GC-MS method for determination of 12 pesticide residues in rice straw,paddy soil and grain was developed.The pesticides in samples was extracted with acetonitrile and cleaned up with florisil column,and then detected by gas chromatography-mass spectrometry.The calibration curves for 10 pesticide residues all had good linear relationships with correlation coefficients not less than 0.998.The spiked recoveries at three concentrations of 0.05,0.10,1.0 mg/L were ranged from 90.5% to 101.2 with relative standard deviations of 2.1%~4.7%.The limits of detection were in the range of 0.005~0.015 mg/L.It was an effective method which fit for the pesticide residues analysis and has high accuracy,precision and sensitivity.

Key concepts: Pesticide residue, Pesticide, Chemistry, Straw, Calibration curve, Detection limit, Soil test, Rice straw

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on pesticide residues analysis in paddy soil,rice straw and grain — Research Paper | ScholarLens