2013Physical Testing and Chemical AnalysisRequires access

HG-ICP-AES Determination of Selenium in Blood Sample

Fei-yue Deng

Open publisher page 0 citations

Abstract

Sample of blood was digested with mixed acid of HClO4-HNO3(1+4),and the content of Se in the solution obtained was determined by HG-ICP-AES with addition of HCl as pre-reductant.In a 6 mol·L-1 HCl medium,hydrides of Se was generated by reacting with 5 g·L-1 NaBH4 solution(dissolved in 20 g·L-1 NaOH solution).Value of detection limits(3s/k) found was 1.8 μg·L-1.The proposed method was used in the determination of Se in 2 blood samples,giving values of recovery in the range of 94.9%-107% with RSD(n=10) less than 3%.

About this research paper

What this paper is about

Sample of blood was digested with mixed acid of HClO4-HNO3(1+4),and the content of Se in the solution obtained was determined by HG-ICP-AES with addition of HCl as pre-reductant.In a 6 mol·L-1 HCl medium,hydrides of Se was generated by reacting with 5 g·L-1 NaBH4 solution(dissolved in 20 g·L-1 NaOH solution).Value of detection limits(3s/k) found was 1.8 μg·L-1.The proposed method was used in the determination of Se in 2 blood samples,giving values of recovery in the range of 94.9%-107% with RSD(n=10) less than 3%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Sample of blood was digested with mixed acid of HClO4-HNO3(1+4),and the content of Se in the solution obtained was determined by HG-ICP-AES with addition of HCl as pre-reductant.In a 6 mol·L-1 HCl medium,hydrides of Se was generated by reacting with 5 g·L-1 NaBH4 solution(dissolved in 20 g·L-1 NaOH solution).Value of detection limits(3s/k) found was 1.8 μg·L-1.The proposed method was used in the determination of Se in 2 blood samples,giving values of recovery in the range of 94.9%-107% with RSD(n=10) less than 3%.

Key concepts: Selenium, Chemistry, Inductively coupled plasma atomic emission spectroscopy, Detection limit, Chromatography, Nuclear chemistry, Analytical Chemistry (journal), Inductively coupled plasma

Related papers

Back to paper searchBrowse research topicsOriginal source
HG-ICP-AES Determination of Selenium in Blood Sample — Research Paper | ScholarLens