2007Shiyong fangshexue zazhiRequires access

The Study of Low - dose CT Scanning Technical Parameters in Neonate Brain

Aiqin Wu, Zheng Wenlong, Xu Chongyong, Jianmin Cheng, Chen Yu, Chen Ting-gang

Open publisher page 0 citations

Abstract

Objective To investigate the optimal technical parameters of low-dose CT scanning in neonate brain so that to reduce the radiation dose.Methods 150 neonates undergone CT scanning of head were randomly divided into five groups averagely.The technical parameters included:tube voltage 120 kV,slice thickness and gap 6 mm,tube current 250,200,150,100 and 50 mAs respectively for scanning the whole brain.The CT value of ROI and standard deviation(SD) were measured in the region of left basal nucleus.The weighted CT dose index(CTDIw),dose length product(DLP),noise and imaging quality were blindly evaluated in five different dose groups.Results (1)With the scanning dose reduced,CTDIw and DLP were evidently reduced,the 50 mAs group was only 20% of the conventional dose group;(2) The imaging quality in 50 mAs group was better and general in majority,in 100 mAs and above groups was good and better in majority.The imaging quality decreased with mAs reduced;(3)The imaging noise in 50 mAs group was heavy,but it could still demonstrate intracranial normal structure and lesion.The imaging quality could be improved through adjusting the window width and window level,and it did not influence the diagnosis on the whole.Conclusion The imaging quality using 50 mAs during CT scanning of head in neonate is certainly decreased, but do not influence the diagnosis and can protect newborns effectively undergone high radiation dose.

About this research paper

What this paper is about

Objective To investigate the optimal technical parameters of low-dose CT scanning in neonate brain so that to reduce the radiation dose.Methods 150 neonates undergone CT scanning of head were randomly divided into five groups averagely.The technical parameters included:tube voltage 120 kV,slice thickness and gap 6 mm,tube current 250,200,150,100 and 50 mAs respectively for scanning the whole brain.The CT value of ROI and standard deviation(SD) were measured in the region of left basal nucleus.The weighted CT dose index(CTDIw),dose length product(DLP),noise and imaging quality were blindly evaluated in five different dose groups.Results (1)With the scanning dose reduced,CTDIw and DLP were evidently reduced,the 50 mAs group was only 20% of the conventional dose group;(2) The imaging quality in 50 mAs group was better and general in majority,in 100 mAs and above groups was good and better in majority.The imaging quality decreased with mAs reduced;(3)The imaging noise in 50 mAs group was heavy,but it could still demonstrate intracranial normal structure and lesion.The imaging quality could be improved through adjusting the window width and window level,and it did not influence the diagnosis on the whole.Conclusion The imaging quality using 50 mAs during CT scanning of head in neonate is certainly decreased, but do not influence the diagnosis and can protect newborns effectively undergone high radiation dose.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the optimal technical parameters of low-dose CT scanning in neonate brain so that to reduce the radiation dose.Methods 150 neonates undergone CT scanning of head were randomly divided into five groups averagely.The technical parameters included:tube voltage 120 kV,slice thickness and gap 6 mm,tube current 250,200,150,100 and 50 mAs respectively for scanning the whole brain.The CT value of ROI and standard deviation(SD) were measured in the region of left basal nucleus.The weighted CT dose index(CTDIw),dose length product(DLP),noise and imaging quality were blindly evaluated in five different dose groups.Results (1)With the scanning dose reduced,CTDIw and DLP were evidently reduced,the 50 mAs group was only 20% of the conventional dose group;(2) The imaging quality in 50 mAs group was better and general in majority,in 100 mAs and above groups was good and better in majority.The imaging quality decreased with mAs reduced;(3)The imaging noise in 50 mAs group was heavy,but it could still demonstrate intracranial normal structure and lesion.The imaging quality could be improved through adjusting the window width and window level,and it did not influence the diagnosis on the whole.Conclusion The imaging quality using 50 mAs during CT scanning of head in neonate is certainly decreased, but do not influence the diagnosis and can protect newborns effectively undergone high radiation dose.

Key concepts: Medicine, Nuclear medicine, Radiation dose, Image quality, Effective dose (radiation), Image noise, Radiation exposure, Pencil-beam scanning