Investigation on Polarograghy of Chloram-phenicol

Luo Yu-xiaand

Open publisher page 0 citations

Abstract

A sensitive derivative reduction peak of chlo- ramphenicol was found by single-sweep Oscillopolaro- graphy in 0. 1 mol/L KCl. The peak potential is -0.74 V (vs. SCE). The relationship between peak current and the concentration of chloramphenicol was linear in the range of 1. 5×10-7~ 2×10-5mol/L. The detection limit was 2.0×10-8mol/L. The electro- chemical behavious of chloramphenicol at Hg electrode and its adsorptive properties were also explored. The proposed method was applied to the determination of chloramphenicol in samples. The recovery was in the range of 96.9%~100.3%.

About this research paper

What this paper is about

A sensitive derivative reduction peak of chlo- ramphenicol was found by single-sweep Oscillopolaro- graphy in 0. 1 mol/L KCl. The peak potential is -0.74 V (vs. SCE). The relationship between peak current and the concentration of chloramphenicol was linear in the range of 1. 5×10-7~ 2×10-5mol/L. The detection limit was 2.0×10-8mol/L. The electro- chemical behavious of chloramphenicol at Hg electrode and its adsorptive properties were also explored. The proposed method was applied to the determination of chloramphenicol in samples. The recovery was in the range of 96.9%~100.3%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A sensitive derivative reduction peak of chlo- ramphenicol was found by single-sweep Oscillopolaro- graphy in 0. 1 mol/L KCl. The peak potential is -0.74 V (vs. SCE). The relationship between peak current and the concentration of chloramphenicol was linear in the range of 1. 5×10-7~ 2×10-5mol/L. The detection limit was 2.0×10-8mol/L. The electro- chemical behavious of chloramphenicol at Hg electrode and its adsorptive properties were also explored. The proposed method was applied to the determination of chloramphenicol in samples. The recovery was in the range of 96.9%~100.3%.

Key concepts: Chemistry, Chloramphenicol, Detection limit, Analytical Chemistry (journal), Derivative (finance), Electrode, Linear range, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Investigation on Polarograghy of Chloram-phenicol — Research Paper | ScholarLens