The Diagnosis Value of Three Dimensional Contast-enhanced Magnetic Resonance Angiography in Carotial Stenosis
Zhang Xin-bao
Abstract
Zhang Xin-bao
Abstract
Objective To assess the diagnosis value of three dimensional contrast-enhanced magnetic resonance angiography(3D CE-MRA) in carotid stenosis.Methods Thirty-two patients with carodid stenosis underwent 3D CE-MRA and digital substraction angiography(DSA)contemporaneously,and measure the diameter of stenosis in carotid,and evaluated the result between two methods.Results In this group 39 carotid stenosises were found by 3D CE-MRA image,among them 37 stenosises were diagnosed with both examinations,two stenosises were highly suspected as no carotid stenosis underwent 3D CE-MRA.The sensitivity of 3D CE-MRA was 100%,the specificity 97.8%~99%,and the acaucacy 97.9%~98.5%(K=0.928~1) in 3D Craniocervical artery.As in carvernous portion of internal carotid artery the sensistirity was 100%,the specficity 92.5%,and the accuracy 93.5%(K=0.657).Conclusion 3D CE-MRA have dsmonstrated the stenosis of craniocervical arteries with reliability and can take place of DSA.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To assess the diagnosis value of three dimensional contrast-enhanced magnetic resonance angiography(3D CE-MRA) in carotid stenosis.Methods Thirty-two patients with carodid stenosis underwent 3D CE-MRA and digital substraction angiography(DSA)contemporaneously,and measure the diameter of stenosis in carotid,and evaluated the result between two methods.Results In this group 39 carotid stenosises were found by 3D CE-MRA image,among them 37 stenosises were diagnosed with both examinations,two stenosises were highly suspected as no carotid stenosis underwent 3D CE-MRA.The sensitivity of 3D CE-MRA was 100%,the specificity 97.8%~99%,and the acaucacy 97.9%~98.5%(K=0.928~1) in 3D Craniocervical artery.As in carvernous portion of internal carotid artery the sensistirity was 100%,the specficity 92.5%,and the accuracy 93.5%(K=0.657).Conclusion 3D CE-MRA have dsmonstrated the stenosis of craniocervical arteries with reliability and can take place of DSA.
Key concepts: Stenosis, Medicine, Digital subtraction angiography, Magnetic resonance angiography, Radiology, Carotid arteries, Magnetic resonance imaging, Angiography