1991中国化学快报:英文版Requires access

THE STUDY OF LUMINOL-H_2O_2-IO_4~--S~(2-)CHEMILUMINESCENCE SYSTEM AND ITS APPLICATION

Xi Li

Open publisher page 0 citations

Abstract

This paper reports a new chemiluminescence system i.e.luminol- H_2O_2-IO_4~- catalyzed by sulphide ion(S~(2-)).Based on this catalysis,a new chemiluminescence(CL)method for the determination of trace S~(2-)is pro- posed.The detection limit is 0.2μg/LS~(2-),the linear dynamic range is 5μg to 100βμg/L S~(2-)and the variation coefficient at an sulphide concentration of 100μg/L S~(2-)is 4.5%(n=10).The method has been satisfactory applied to the determination of trace sulphide ion in water.

About this research paper

What this paper is about

This paper reports a new chemiluminescence system i.e.luminol- H_2O_2-IO_4~- catalyzed by sulphide ion(S~(2-)).Based on this catalysis,a new chemiluminescence(CL)method for the determination of trace S~(2-)is pro- posed.The detection limit is 0.2μg/LS~(2-),the linear dynamic range is 5μg to 100βμg/L S~(2-)and the variation coefficient at an sulphide concentration of 100μg/L S~(2-)is 4.5%(n=10).The method has been satisfactory applied to the determination of trace sulphide ion in water.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper reports a new chemiluminescence system i.e.luminol- H_2O_2-IO_4~- catalyzed by sulphide ion(S~(2-)).Based on this catalysis,a new chemiluminescence(CL)method for the determination of trace S~(2-)is pro- posed.The detection limit is 0.2μg/LS~(2-),the linear dynamic range is 5μg to 100βμg/L S~(2-)and the variation coefficient at an sulphide concentration of 100μg/L S~(2-)is 4.5%(n=10).The method has been satisfactory applied to the determination of trace sulphide ion in water.

Key concepts: Chemiluminescence, Luminol, Detection limit, Chemistry, Catalysis, Linear range, Trace Amounts, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
THE STUDY OF LUMINOL-H_2O_2-IO_4~--S~(2-)CHEMILUMINESCENCE SYSTEM AND ITS APPLICATION — Research Paper | ScholarLens