2013Guizhou kexueRequires access

Graphite Furnace Atomic Absorption Spectrometry Determination of Molybdenum in Food Formulation with Microwave Digestion Technique

Xie Fen

Open publisher page 0 citations

Abstract

Determination of molybdenum in food formulation applies microwave digestion technique.It is determined with nitric acid in a high—pressure microwave oven and then analyzed by graphite furnace atomic absorption spectrometry.The detection limit is 0.7ng/mL,The calibration lines are linear in the range of 0 ~ 100ng/mL,and the recoveries of these materials range from 95.1% to 104.8%.The method is established for the first time,rapid,accurate and low on the detection limit.

About this research paper

What this paper is about

Determination of molybdenum in food formulation applies microwave digestion technique.It is determined with nitric acid in a high—pressure microwave oven and then analyzed by graphite furnace atomic absorption spectrometry.The detection limit is 0.7ng/mL,The calibration lines are linear in the range of 0 ~ 100ng/mL,and the recoveries of these materials range from 95.1% to 104.8%.The method is established for the first time,rapid,accurate and low on the detection limit.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Determination of molybdenum in food formulation applies microwave digestion technique.It is determined with nitric acid in a high—pressure microwave oven and then analyzed by graphite furnace atomic absorption spectrometry.The detection limit is 0.7ng/mL,The calibration lines are linear in the range of 0 ~ 100ng/mL,and the recoveries of these materials range from 95.1% to 104.8%.The method is established for the first time,rapid,accurate and low on the detection limit.

Key concepts: Graphite furnace atomic absorption, Microwave digestion, Detection limit, Molybdenum, Graphite, Nitric acid, Calibration curve, Atomic absorption spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Graphite Furnace Atomic Absorption Spectrometry Determination of Molybdenum in Food Formulation with Microwave Digestion Technique — Research Paper | ScholarLens