2005Journal of Guizhou University of TechnologyRequires access

Graphite Furnace Atomic Absorption Spectrometry Determination of Aluminium in Viscera with Microwave Digestion Technique

HE Jin-lin

Open publisher page 0 citations

Abstract

Determination of aluminium in viscera is conducted by adopting microwave digestion technique. It is determined with nitric acid in a high - pressure microwave oven and then analyzed by graphite furnace atomic absorption spectrometry. The detection limit is 0. 91ng/ml,The calibration lines are linear in the range of 0-1000 ng/ml,and the recoveries of these materials range from 95. 1% to 104. 8% . The method is simple,accurate and low on the detection limit.

About this research paper

What this paper is about

Determination of aluminium in viscera is conducted by adopting microwave digestion technique. It is determined with nitric acid in a high - pressure microwave oven and then analyzed by graphite furnace atomic absorption spectrometry. The detection limit is 0. 91ng/ml,The calibration lines are linear in the range of 0-1000 ng/ml,and the recoveries of these materials range from 95. 1% to 104. 8% . The method is simple,accurate and low on the detection limit.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Determination of aluminium in viscera is conducted by adopting microwave digestion technique. It is determined with nitric acid in a high - pressure microwave oven and then analyzed by graphite furnace atomic absorption spectrometry. The detection limit is 0. 91ng/ml,The calibration lines are linear in the range of 0-1000 ng/ml,and the recoveries of these materials range from 95. 1% to 104. 8% . The method is simple,accurate and low on the detection limit.

Key concepts: Microwave digestion, Graphite furnace atomic absorption, Detection limit, Nitric acid, Atomic absorption spectroscopy, Microwave oven, Graphite, Aluminium