2012Laboratory Medicine and ClinicRequires access

Detection and clinical analysis of serum cardiac troponin-I and creatine kinase MB isoenzyme in 83 neonates with asphyxia

Yan Chen

Open publisher page 0 citations

Abstract

Objective To investigate the changes of cardiac troponin I(cTnI),creatine kinase MB isoenzyme(CK-MB) and their clinical significance in neonatal asphyxia.Methods 83 neonates with asphyxia(48 cases of mild asphyxia and 35 cases of severe asphyxia) and 30 normal neonates(control group) were detected the values of serum cTnI and CK-MB by the microparticles chemiluminescence and dry chemical analysis.Results The average values of cTnI and CK-MB were(0.03 ± 0.02)ng/mL and(37.0±12.3)U/L for the normal control group,(0.12 ± 0.05)ng/mL and(71.0±19.3)U/L for the mild asphyxia group and(0.19 ± 0.14)ng/mL and(92.0±25.4)U/L for the severe asphyxia group.Conclusion Serum cTnI and CK-MB levels are significantly increased in neonatal asphyxia.Detecting serum cTnI and CK-MB levels can not only be used to determine the extent of myocardial damage by asphyxia,but also indirectly reflect the degree of asphyxia,which is helpful to early diagnosis and treatment.

About this research paper

What this paper is about

Objective To investigate the changes of cardiac troponin I(cTnI),creatine kinase MB isoenzyme(CK-MB) and their clinical significance in neonatal asphyxia.Methods 83 neonates with asphyxia(48 cases of mild asphyxia and 35 cases of severe asphyxia) and 30 normal neonates(control group) were detected the values of serum cTnI and CK-MB by the microparticles chemiluminescence and dry chemical analysis.Results The average values of cTnI and CK-MB were(0.03 ± 0.02)ng/mL and(37.0±12.3)U/L for the normal control group,(0.12 ± 0.05)ng/mL and(71.0±19.3)U/L for the mild asphyxia group and(0.19 ± 0.14)ng/mL and(92.0±25.4)U/L for the severe asphyxia group.Conclusion Serum cTnI and CK-MB levels are significantly increased in neonatal asphyxia.Detecting serum cTnI and CK-MB levels can not only be used to determine the extent of myocardial damage by asphyxia,but also indirectly reflect the degree of asphyxia,which is helpful to early diagnosis and treatment.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the changes of cardiac troponin I(cTnI),creatine kinase MB isoenzyme(CK-MB) and their clinical significance in neonatal asphyxia.Methods 83 neonates with asphyxia(48 cases of mild asphyxia and 35 cases of severe asphyxia) and 30 normal neonates(control group) were detected the values of serum cTnI and CK-MB by the microparticles chemiluminescence and dry chemical analysis.Results The average values of cTnI and CK-MB were(0.03 ± 0.02)ng/mL and(37.0±12.3)U/L for the normal control group,(0.12 ± 0.05)ng/mL and(71.0±19.3)U/L for the mild asphyxia group and(0.19 ± 0.14)ng/mL and(92.0±25.4)U/L for the severe asphyxia group.Conclusion Serum cTnI and CK-MB levels are significantly increased in neonatal asphyxia.Detecting serum cTnI and CK-MB levels can not only be used to determine the extent of myocardial damage by asphyxia,but also indirectly reflect the degree of asphyxia,which is helpful to early diagnosis and treatment.

Key concepts: Asphyxia, Creatine kinase, Troponin I, Medicine, Perinatal asphyxia, Clinical significance, Internal medicine, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Detection and clinical analysis of serum cardiac troponin-I and creatine kinase MB isoenzyme in 83 neonates with asphyxia — Research Paper | ScholarLens