Clinical application of CT-guided fine-needle percutaneous biopsy in the diagnosis of lung lesions (An analysis of 117 cases)
Zhu Xiaohu
Abstract
Zhu Xiaohu
Abstract
Objective To evaluate the value of CT - guided fine - needle percutaneous biopsy in patient with lung lesions. Methods CT - guided fine - needle percutaneous biopsy were performed in 117 patients with lung lesions, included 66 masses, 42 nodules, 9 lung consolidations. 18 G needles had been used to biopsy from the best - chosen level and situs. Cytologic and histologic studies were done after biopsy. Result The successful puncture rate were 94.1% .Of 117 cases studied,84 were proved to be cancers.77cases were confirmed by biopsy.The sensitivity of biopsy was 91.7% and specificity of biopsy was 82.5 % . Teases were false negative . No false positive was found. 33 cases were benign lesions, confirmed by pathology and clinical course. 7cases occured pneumthrax (14.5 % ), 2 of them need chest tube drainge. Conclusion CT - guided fine - needle percutaneous biopsy is a successful efficient and safty diagnostic method with high accuracy and few complications. It can provide evidence for clinical diagnosis and it is suggested to be used more widely .
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the value of CT - guided fine - needle percutaneous biopsy in patient with lung lesions. Methods CT - guided fine - needle percutaneous biopsy were performed in 117 patients with lung lesions, included 66 masses, 42 nodules, 9 lung consolidations. 18 G needles had been used to biopsy from the best - chosen level and situs. Cytologic and histologic studies were done after biopsy. Result The successful puncture rate were 94.1% .Of 117 cases studied,84 were proved to be cancers.77cases were confirmed by biopsy.The sensitivity of biopsy was 91.7% and specificity of biopsy was 82.5 % . Teases were false negative . No false positive was found. 33 cases were benign lesions, confirmed by pathology and clinical course. 7cases occured pneumthrax (14.5 % ), 2 of them need chest tube drainge. Conclusion CT - guided fine - needle percutaneous biopsy is a successful efficient and safty diagnostic method with high accuracy and few complications. It can provide evidence for clinical diagnosis and it is suggested to be used more widely .
Key concepts: Medicine, Biopsy, Radiology, Percutaneous, Lung biopsy, Lung, Percutaneous biopsy, Internal medicine