2014•Hebei ke-ji daxue xuebaoOpen access

Determination of heavy metals in soil by flame atomic absorption spectrometry using graphite digestion device

Yang Jingp

Open full text 0 citations

Abstract

This study established a method for determination of heavy metals such as Cu,Zn,Ni,Cr,and Mn in soil by flame atomic absorption spectrometry using graphite digestion device.A pretreatment process was confirmed after the pretreatment condition such as digestion system and amount of sample for digestion were optimized.The detection limits are 0.62,0.48,0.45,0.53and 0.50mg/kg for Cu,Cr,Zn,Ni and Mn,respectively.Recoveries are between 96.5%and 105%.RSD are between 0.8%and 2.0%.

About this research paper

What this paper is about

This study established a method for determination of heavy metals such as Cu,Zn,Ni,Cr,and Mn in soil by flame atomic absorption spectrometry using graphite digestion device.A pretreatment process was confirmed after the pretreatment condition such as digestion system and amount of sample for digestion were optimized.The detection limits are 0.62,0.48,0.45,0.53and 0.50mg/kg for Cu,Cr,Zn,Ni and Mn,respectively.Recoveries are between 96.5%and 105%.RSD are between 0.8%and 2.0%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study established a method for determination of heavy metals such as Cu,Zn,Ni,Cr,and Mn in soil by flame atomic absorption spectrometry using graphite digestion device.A pretreatment process was confirmed after the pretreatment condition such as digestion system and amount of sample for digestion were optimized.The detection limits are 0.62,0.48,0.45,0.53and 0.50mg/kg for Cu,Cr,Zn,Ni and Mn,respectively.Recoveries are between 96.5%and 105%.RSD are between 0.8%and 2.0%.

Key concepts: Atomic absorption spectroscopy, Digestion (alchemy), Graphite furnace atomic absorption, Graphite, Chemistry, Heavy metals, Mass spectrometry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of heavy metals in soil by flame atomic absorption spectrometry using graphite digestion device — Research Paper | ScholarLens