2011•Physical Testing and Chemical AnalysisRequires access

Rapid HPLC Determination of Malachite Green in Water with Solid Phase Micro-extraction

Sui Wang

Open publisher page 0 citations

Abstract

HPLC with sample treatment by solid phase micro-extraction(SPME) was applied to the determination of malachite green in water samples.To attain a higher efficiency in SPME,the 85 μm PA coating was applied to the micro-extractor,and the extraction was carried out for 15 min.The Shim-pack VP-ODS C18 column was used as the stationary phase,and a mixture of 50 mmol·L-1 ammonium acetate solution of pH 4.5 and acetonitrile(20+80) was used as the mobile phase for elution.Detection at 595 nm was adopted.Linearity range of malachite green was kept in the range of 0.05-2 mg·L-1,with detection limit(3S/N) of 0.003 mg·L-1.A sample of fish pond water was analyzed by this method,and test for recovery was made on this sample as matrix by standard addition method giving results in the range of 98.1%-109.6%.

About this research paper

What this paper is about

HPLC with sample treatment by solid phase micro-extraction(SPME) was applied to the determination of malachite green in water samples.To attain a higher efficiency in SPME,the 85 μm PA coating was applied to the micro-extractor,and the extraction was carried out for 15 min.The Shim-pack VP-ODS C18 column was used as the stationary phase,and a mixture of 50 mmol·L-1 ammonium acetate solution of pH 4.5 and acetonitrile(20+80) was used as the mobile phase for elution.Detection at 595 nm was adopted.Linearity range of malachite green was kept in the range of 0.05-2 mg·L-1,with detection limit(3S/N) of 0.003 mg·L-1.A sample of fish pond water was analyzed by this method,and test for recovery was made on this sample as matrix by standard addition method giving results in the range of 98.1%-109.6%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

HPLC with sample treatment by solid phase micro-extraction(SPME) was applied to the determination of malachite green in water samples.To attain a higher efficiency in SPME,the 85 μm PA coating was applied to the micro-extractor,and the extraction was carried out for 15 min.The Shim-pack VP-ODS C18 column was used as the stationary phase,and a mixture of 50 mmol·L-1 ammonium acetate solution of pH 4.5 and acetonitrile(20+80) was used as the mobile phase for elution.Detection at 595 nm was adopted.Linearity range of malachite green was kept in the range of 0.05-2 mg·L-1,with detection limit(3S/N) of 0.003 mg·L-1.A sample of fish pond water was analyzed by this method,and test for recovery was made on this sample as matrix by standard addition method giving results in the range of 98.1%-109.6%.

Key concepts: Malachite green, Chromatography, Detection limit, Solid phase extraction, Ammonium acetate, Elution, Extraction (chemistry), Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid HPLC Determination of Malachite Green in Water with Solid Phase Micro-extraction — Research Paper | ScholarLens