2009•Chemia AnalitycznaRequires access

Solid phase extraction using a column with a monolithic molecuraly imprinted epoxy resin-based polymeric stationary phase : HPLC determination of malachite green in fish and water samples

Sui Wang, LI Hai-long, Guo Zhiyong, Zhang Hui-na, Yan-Ling Tao, Dan‐Yi Wei

Open publisher page 3 citations

Abstract

A column with a novel monolithic molecularly imprinted polymer (MIP)-based stationary phase with malachite green (MG) as template molecules was prepared. The synthesized MIP was characterized by IR and SEM. Extraction conditions on MIPs were optimized. MG and some other compounds were employed for selectivity tests. River water samples were spiked with MG at the concentration 20-500 ng mL -1 ; extraction was performed using a MISPE column and detection was accomplished by HPLC. The achieved recoveries were in the range 95.06-100.13%; relative standard deviation was 0.025-6.63%. MG concentrations in three natural water and fish samples were 2.65, 2.60, 2.36 and 5.63 ng mL -1 , respectively.

About this research paper

What this paper is about

A column with a novel monolithic molecularly imprinted polymer (MIP)-based stationary phase with malachite green (MG) as template molecules was prepared. The synthesized MIP was characterized by IR and SEM. Extraction conditions on MIPs were optimized. MG and some other compounds were employed for selectivity tests. River water samples were spiked with MG at the concentration 20-500 ng mL -1 ; extraction was performed using a MISPE column and detection was accomplished by HPLC. The achieved recoveries were in the range 95.06-100.13%; relative standard deviation was 0.025-6.63%. MG concentrations in three natural water and fish samples were 2.65, 2.60, 2.36 and 5.63 ng mL -1 , respectively.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A column with a novel monolithic molecularly imprinted polymer (MIP)-based stationary phase with malachite green (MG) as template molecules was prepared. The synthesized MIP was characterized by IR and SEM. Extraction conditions on MIPs were optimized. MG and some other compounds were employed for selectivity tests. River water samples were spiked with MG at the concentration 20-500 ng mL -1 ; extraction was performed using a MISPE column and detection was accomplished by HPLC. The achieved recoveries were in the range 95.06-100.13%; relative standard deviation was 0.025-6.63%. MG concentrations in three natural water and fish samples were 2.65, 2.60, 2.36 and 5.63 ng mL -1 , respectively.

Key concepts: Malachite green, Chemistry, Chromatography, Molecularly imprinted polymer, High-performance liquid chromatography, Solid phase extraction, Extraction (chemistry), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Solid phase extraction using a column with a monolithic molecuraly imprinted epoxy resin-based polymeric stationary phase : HPLC determination of malachite green in fish and water samples — Research Paper | ScholarLens