2006•Turbine TechnologyRequires access

Analysis and Improvement on the Lower Ratio of Putting into Operation of High-pressure Heater

Wang Yun-min

Open publisher page 0 citations

Abstract

The lower ratio of putting into operation of high-pressure heater is an important factor which affects the safe and economical operation of turbine-generator unit in a power plant.Based on the high-pressure heater of 300MW unit in a power plant,the reason for the lower ratio of putting into operation of high-pressure heater is analyzed,the thermo-economical performance is computed with the method of equivalent enthalpy drop,a lot of good ideas are put forward,and the improvement measures are taken.So far the regular service of high-pressure heater is kept,and a good economic effectiveness is gained.

About this research paper

What this paper is about

The lower ratio of putting into operation of high-pressure heater is an important factor which affects the safe and economical operation of turbine-generator unit in a power plant.Based on the high-pressure heater of 300MW unit in a power plant,the reason for the lower ratio of putting into operation of high-pressure heater is analyzed,the thermo-economical performance is computed with the method of equivalent enthalpy drop,a lot of good ideas are put forward,and the improvement measures are taken.So far the regular service of high-pressure heater is kept,and a good economic effectiveness is gained.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The lower ratio of putting into operation of high-pressure heater is an important factor which affects the safe and economical operation of turbine-generator unit in a power plant.Based on the high-pressure heater of 300MW unit in a power plant,the reason for the lower ratio of putting into operation of high-pressure heater is analyzed,the thermo-economical performance is computed with the method of equivalent enthalpy drop,a lot of good ideas are put forward,and the improvement measures are taken.So far the regular service of high-pressure heater is kept,and a good economic effectiveness is gained.

Key concepts: Engineering, Overall pressure ratio, Pressure drop, High pressure, Power station, Steam turbine, Power (physics), Unit (ring theory)

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis and Improvement on the Lower Ratio of Putting into Operation of High-pressure Heater — Research Paper | ScholarLens