2009•China Medical HeraldRequires access

Improvement on quality standard for Yinhuang Injection

Huiqin Zhou

Open publisher page 0 citations

Abstract

Objective: To improve the quality standard of Yinhuang Injection. Methods: HPLC was adopted for the determination of the chlorogenic acid and baicalin at the same time. Agilent-C18 (150 mm×4.6 mm,5 μm) was used,the mobile phase was composed of methanol-0.4% phosphoric acid(30∶60)with the flow rate of 1.0 ml/min,the detective wavelength was set at 327 nm for chlorogenic acid and 276 nm for baicalin,the column temperature was maintained at 30℃. Results: The linear range of chlorogenic acid was 0.010 83-0.108 30 mg/ml (r=0.999 44),the average recovery was 100.24% with RSD of 1.54%. The linear range of baicalin was 0.015 15-0.151 50 mg/ml (r=0.999 99),the average recovery was 100.48% with RSD of 0.97%. Conclusion: The method is simple,accurate,and can be used for the quality control of Yin-huang Injection.

About this research paper

What this paper is about

Objective: To improve the quality standard of Yinhuang Injection. Methods: HPLC was adopted for the determination of the chlorogenic acid and baicalin at the same time. Agilent-C18 (150 mm×4.6 mm,5 μm) was used,the mobile phase was composed of methanol-0.4% phosphoric acid(30∶60)with the flow rate of 1.0 ml/min,the detective wavelength was set at 327 nm for chlorogenic acid and 276 nm for baicalin,the column temperature was maintained at 30℃. Results: The linear range of chlorogenic acid was 0.010 83-0.108 30 mg/ml (r=0.999 44),the average recovery was 100.24% with RSD of 1.54%. The linear range of baicalin was 0.015 15-0.151 50 mg/ml (r=0.999 99),the average recovery was 100.48% with RSD of 0.97%. Conclusion: The method is simple,accurate,and can be used for the quality control of Yin-huang Injection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To improve the quality standard of Yinhuang Injection. Methods: HPLC was adopted for the determination of the chlorogenic acid and baicalin at the same time. Agilent-C18 (150 mm×4.6 mm,5 μm) was used,the mobile phase was composed of methanol-0.4% phosphoric acid(30∶60)with the flow rate of 1.0 ml/min,the detective wavelength was set at 327 nm for chlorogenic acid and 276 nm for baicalin,the column temperature was maintained at 30℃. Results: The linear range of chlorogenic acid was 0.010 83-0.108 30 mg/ml (r=0.999 44),the average recovery was 100.24% with RSD of 1.54%. The linear range of baicalin was 0.015 15-0.151 50 mg/ml (r=0.999 99),the average recovery was 100.48% with RSD of 0.97%. Conclusion: The method is simple,accurate,and can be used for the quality control of Yin-huang Injection.

Key concepts: Baicalin, Chlorogenic acid, Phosphoric acid, Chromatography, Medicine, High-performance liquid chromatography, Quality standard, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Improvement on quality standard for Yinhuang Injection — Research Paper | ScholarLens