2007Unpublished venueRequires access

Determination of paeoniflorin in Xianglian Huazhi Wan by HPLC

Yufang Li

Open publisher page 0 citations

Abstract

OBJECTIVE To establish a HPLC method for the determination of Paeoniflorin in Xianglian Huazhi Wan.METHODS Kromasil C18 column(250 mm×4.6 mm,5 μm) was used with methanol-water(25∶75) as the mobile phase;The detection wavelength was 230 nm and the flow rate was 1.0 ml/min with the column temperature of 30 ℃.RESULTS The linear range was 14.24~85.44 μg/ml(r=0.999 7);The average recovery rate was 99.19%,RSD=1.28%.CONCLUSION The method was sensitive,accurate and reproducible.It is suitable for determining the content of Paeoniflorin in Xianglian Huazhi Wan.

About this research paper

What this paper is about

OBJECTIVE To establish a HPLC method for the determination of Paeoniflorin in Xianglian Huazhi Wan.METHODS Kromasil C18 column(250 mm×4.6 mm,5 μm) was used with methanol-water(25∶75) as the mobile phase;The detection wavelength was 230 nm and the flow rate was 1.0 ml/min with the column temperature of 30 ℃.RESULTS The linear range was 14.24~85.44 μg/ml(r=0.999 7);The average recovery rate was 99.19%,RSD=1.28%.CONCLUSION The method was sensitive,accurate and reproducible.It is suitable for determining the content of Paeoniflorin in Xianglian Huazhi Wan.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To establish a HPLC method for the determination of Paeoniflorin in Xianglian Huazhi Wan.METHODS Kromasil C18 column(250 mm×4.6 mm,5 μm) was used with methanol-water(25∶75) as the mobile phase;The detection wavelength was 230 nm and the flow rate was 1.0 ml/min with the column temperature of 30 ℃.RESULTS The linear range was 14.24~85.44 μg/ml(r=0.999 7);The average recovery rate was 99.19%,RSD=1.28%.CONCLUSION The method was sensitive,accurate and reproducible.It is suitable for determining the content of Paeoniflorin in Xianglian Huazhi Wan.

Key concepts: Paeoniflorin, Chromatography, High-performance liquid chromatography, Linear range, Chemistry, Analytical Chemistry (journal), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of paeoniflorin in Xianglian Huazhi Wan by HPLC — Research Paper | ScholarLens