2000Unpublished venueRequires access

Determination of Iron in the RHKHAEMATICTONIC

Yi Wang

Open publisher page 0 citations

Abstract

Objective:To establish a Flow Injection analysis (FIA) method for the determination of iron in the Hongtao K Sheng Xue Ji.Methods:A Flow Injection analysis (FIA) method was used. λ is 475nm, NH 4 SCN is used as a colored.Results:The calibration curve is linear (r=0.9999) within the range of 13.4-40.2μg/ml for iron, The average recovery is 99.35%, RSD=0.72%, The metal ions Zn 2+ , Mg 2+ , Al 3+ , Ca 2+ and Cu 2+ don't interfere in analysis.Conclusion:This method is simple, accurated and steady and can be used for the quality control of preparation.

About this research paper

What this paper is about

Objective:To establish a Flow Injection analysis (FIA) method for the determination of iron in the Hongtao K Sheng Xue Ji.Methods:A Flow Injection analysis (FIA) method was used. λ is 475nm, NH 4 SCN is used as a colored.Results:The calibration curve is linear (r=0.9999) within the range of 13.4-40.2μg/ml for iron, The average recovery is 99.35%, RSD=0.72%, The metal ions Zn 2+ , Mg 2+ , Al 3+ , Ca 2+ and Cu 2+ don't interfere in analysis.Conclusion:This method is simple, accurated and steady and can be used for the quality control of preparation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a Flow Injection analysis (FIA) method for the determination of iron in the Hongtao K Sheng Xue Ji.Methods:A Flow Injection analysis (FIA) method was used. λ is 475nm, NH 4 SCN is used as a colored.Results:The calibration curve is linear (r=0.9999) within the range of 13.4-40.2μg/ml for iron, The average recovery is 99.35%, RSD=0.72%, The metal ions Zn 2+ , Mg 2+ , Al 3+ , Ca 2+ and Cu 2+ don't interfere in analysis.Conclusion:This method is simple, accurated and steady and can be used for the quality control of preparation.

Key concepts: Flow injection analysis, Calibration curve, Chemistry, Chromatography, Quantitative analysis (chemistry), Analytical Chemistry (journal), Metal, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Iron in the RHKHAEMATICTONIC — Research Paper | ScholarLens