2009•Urban Environment & Urban EcologyRequires access

Countermeasures against Interference in Measurement of Sulfur Dioxide in Flue Gases by Using Fixed-Potential Electrolysis Method

Zhengping Hao

Open publisher page 0 citations

Abstract

The interference of humidity,negative pressure,and the gases,such as NO2 and CO were discussed on the measurement of sulfur dioxide in flue gases by using Fixed-Potential Electrolysis Method.Based on the in-situ monitoring,the simulation test was introduced to analyse their causes and impacts.Methods for eliminating the interference of the humidity,negative pressure and gases were discussed,the countermeasures and advice were put forward for improving the measurement of sulfur dioxide in flue gases by using Fixed-Potential Electrolysis Method.

About this research paper

What this paper is about

The interference of humidity,negative pressure,and the gases,such as NO2 and CO were discussed on the measurement of sulfur dioxide in flue gases by using Fixed-Potential Electrolysis Method.Based on the in-situ monitoring,the simulation test was introduced to analyse their causes and impacts.Methods for eliminating the interference of the humidity,negative pressure and gases were discussed,the countermeasures and advice were put forward for improving the measurement of sulfur dioxide in flue gases by using Fixed-Potential Electrolysis Method.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The interference of humidity,negative pressure,and the gases,such as NO2 and CO were discussed on the measurement of sulfur dioxide in flue gases by using Fixed-Potential Electrolysis Method.Based on the in-situ monitoring,the simulation test was introduced to analyse their causes and impacts.Methods for eliminating the interference of the humidity,negative pressure and gases were discussed,the countermeasures and advice were put forward for improving the measurement of sulfur dioxide in flue gases by using Fixed-Potential Electrolysis Method.

Key concepts: Flue gas, Sulfur dioxide, Electrolysis, Humidity, Interference (communication), Chemistry, Waste management, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Countermeasures against Interference in Measurement of Sulfur Dioxide in Flue Gases by Using Fixed-Potential Electrolysis Method — Research Paper | ScholarLens