2010•Environmental Monitoring and ForewarningRequires access

Problems and Solution on the Interference in Sulfur Dioxide Analysis with Fixed-potential Electrolysis

Bai Song

Open publisher page 0 citations

Abstract

Gas pressure,moisture content and interference gas could affect sulphur dioxide concentration monitoring,and sometimes even produce a gravely deviates.Based on the principle of sulfur dioxide measured by fixed-potential electrolysis,we proposed several solutions:adding heating/condensing function on the sampling tube,keeping a suitable sampling flow and using prepositive pump to reduce the subpressure when it is beyond 2.3kPa,calculating the critical concentration,modifying the software,and so on.

About this research paper

What this paper is about

Gas pressure,moisture content and interference gas could affect sulphur dioxide concentration monitoring,and sometimes even produce a gravely deviates.Based on the principle of sulfur dioxide measured by fixed-potential electrolysis,we proposed several solutions:adding heating/condensing function on the sampling tube,keeping a suitable sampling flow and using prepositive pump to reduce the subpressure when it is beyond 2.3kPa,calculating the critical concentration,modifying the software,and so on.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Gas pressure,moisture content and interference gas could affect sulphur dioxide concentration monitoring,and sometimes even produce a gravely deviates.Based on the principle of sulfur dioxide measured by fixed-potential electrolysis,we proposed several solutions:adding heating/condensing function on the sampling tube,keeping a suitable sampling flow and using prepositive pump to reduce the subpressure when it is beyond 2.3kPa,calculating the critical concentration,modifying the software,and so on.

Key concepts: Sulfur dioxide, Electrolysis, Interference (communication), Chemistry, Sampling (signal processing), Flow (mathematics), Sulfur, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Problems and Solution on the Interference in Sulfur Dioxide Analysis with Fixed-potential Electrolysis — Research Paper | ScholarLens