2007Metallurgical AnalysisRequires access

Determination of trace elements in steel by high resolution inductively coupled plasma mass spectrometry without matrix separation

Wang Yang-ping

Open publisher page 0 citations

Abstract

In order to meet strict increasingly quanlity requirement in iron and steel production,it is necessary to reduce the determination low limits of trace elements in steel to the μg/g order.In this study,trace elements like B,Al,P,Cr,Pb,Sn,Sb,As,Bi in μg/g or sub μg/g level in steel were determined fast and accurately.Steel samples were dissolved with nitric acid,hydrochloric acid and hydrofluoric acid by electrothermal heating or microwave digestion.After diluted,the solution was measured by high resolution inductively couled plasma-mass spectrometry(HR-ICP-MS)without any matrix separation or internal standard.It had good precision giving RSDs(n=10)of below 5%except for 10.5% of Bi.The detection limits of the method was lower than 0.1 μg/g,except for 0.144 μg/g of P.The recoveries of 86%-106% were satisfied,except for 81%-120% of As.The measured values tally with the certified values.The method is extraordinary suitable for the determination of trace elements in steel.

About this research paper

What this paper is about

In order to meet strict increasingly quanlity requirement in iron and steel production,it is necessary to reduce the determination low limits of trace elements in steel to the μg/g order.In this study,trace elements like B,Al,P,Cr,Pb,Sn,Sb,As,Bi in μg/g or sub μg/g level in steel were determined fast and accurately.Steel samples were dissolved with nitric acid,hydrochloric acid and hydrofluoric acid by electrothermal heating or microwave digestion.After diluted,the solution was measured by high resolution inductively couled plasma-mass spectrometry(HR-ICP-MS)without any matrix separation or internal standard.It had good precision giving RSDs(n=10)of below 5%except for 10.5% of Bi.The detection limits of the method was lower than 0.1 μg/g,except for 0.144 μg/g of P.The recoveries of 86%-106% were satisfied,except for 81%-120% of As.The measured values tally with the certified values.The method is extraordinary suitable for the determination of trace elements in steel.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to meet strict increasingly quanlity requirement in iron and steel production,it is necessary to reduce the determination low limits of trace elements in steel to the μg/g order.In this study,trace elements like B,Al,P,Cr,Pb,Sn,Sb,As,Bi in μg/g or sub μg/g level in steel were determined fast and accurately.Steel samples were dissolved with nitric acid,hydrochloric acid and hydrofluoric acid by electrothermal heating or microwave digestion.After diluted,the solution was measured by high resolution inductively couled plasma-mass spectrometry(HR-ICP-MS)without any matrix separation or internal standard.It had good precision giving RSDs(n=10)of below 5%except for 10.5% of Bi.The detection limits of the method was lower than 0.1 μg/g,except for 0.144 μg/g of P.The recoveries of 86%-106% were satisfied,except for 81%-120% of As.The measured values tally with the certified values.The method is extraordinary suitable for the determination of trace elements in steel.

Key concepts: Inductively coupled plasma mass spectrometry, Hydrochloric acid, Hydrofluoric acid, Chemistry, Nitric acid, Matrix (chemical analysis), Analytical Chemistry (journal), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace elements in steel by high resolution inductively coupled plasma mass spectrometry without matrix separation — Research Paper | ScholarLens