2011Central South PharmacyRequires access

Determination of domperidone in human plasma by HPLC-MS/MS

Xiuyun Chen

Open publisher page 0 citations

Abstract

Objective To develop a liquid chromatography-tandem mass spectrometry method to determine domperidone in human plasma.Methods After extraction with ethyl ether,domperidone and internal standard were chromatographically separated on an ultimate C18 column(2.1 mm×150 mm,3 μm) with a mobile phase containing 0.1% formate acid buffer and acetonitrile(30∶70,v/v) at 0.25 mL·min-1.The electronic spray ion tandem mass spectrum with the positive mode and multitude reaction monitor(MRM) were used to detect the analytes.Results The linear range of the calibration curves was 0.2-150 ng·mL-1 for domperidone.Intra-day and inter-day RSD was less than 15%.The methodology recovery ranged 99.8%-105.6%.Conclusion The present method is sensitive,efficient and reliable.The described method has been successfully used for the pharmacokinetic studies of domperidone after oral administration in healthy Chinese volunteers.

About this research paper

What this paper is about

Objective To develop a liquid chromatography-tandem mass spectrometry method to determine domperidone in human plasma.Methods After extraction with ethyl ether,domperidone and internal standard were chromatographically separated on an ultimate C18 column(2.1 mm×150 mm,3 μm) with a mobile phase containing 0.1% formate acid buffer and acetonitrile(30∶70,v/v) at 0.25 mL·min-1.The electronic spray ion tandem mass spectrum with the positive mode and multitude reaction monitor(MRM) were used to detect the analytes.Results The linear range of the calibration curves was 0.2-150 ng·mL-1 for domperidone.Intra-day and inter-day RSD was less than 15%.The methodology recovery ranged 99.8%-105.6%.Conclusion The present method is sensitive,efficient and reliable.The described method has been successfully used for the pharmacokinetic studies of domperidone after oral administration in healthy Chinese volunteers.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a liquid chromatography-tandem mass spectrometry method to determine domperidone in human plasma.Methods After extraction with ethyl ether,domperidone and internal standard were chromatographically separated on an ultimate C18 column(2.1 mm×150 mm,3 μm) with a mobile phase containing 0.1% formate acid buffer and acetonitrile(30∶70,v/v) at 0.25 mL·min-1.The electronic spray ion tandem mass spectrum with the positive mode and multitude reaction monitor(MRM) were used to detect the analytes.Results The linear range of the calibration curves was 0.2-150 ng·mL-1 for domperidone.Intra-day and inter-day RSD was less than 15%.The methodology recovery ranged 99.8%-105.6%.Conclusion The present method is sensitive,efficient and reliable.The described method has been successfully used for the pharmacokinetic studies of domperidone after oral administration in healthy Chinese volunteers.

Key concepts: Domperidone, Chromatography, Selected reaction monitoring, Chemistry, Tandem mass spectrometry, Calibration curve, Analyte, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of domperidone in human plasma by HPLC-MS/MS — Research Paper | ScholarLens