2009Physical Testing and Chemical AnalysisRequires access

ICP-AES Determination of Trace Elements in Violet Grown in Tianshan

Xie Cheng-xi

Open publisher page 1 citations

Abstract

The sample of violet grown in Tianshan, was treated with a mixed solution of HNO_3 and H_2O_2 by wet digestion method, and the contents of trace elements, including B, Cu, K, Mg, Mn, Se, Zn, Cr, Fe and V in the sample solution, were determined by ICP-AES. The detection limits (3s) of the method were less than 0. 015 mg ·L~(-1).The values of recovery of trace elements found by standard addition method were ranged from 95. 4% to 106. 4%, with RSD's (n=6) of 2. 7%.

About this research paper

What this paper is about

The sample of violet grown in Tianshan, was treated with a mixed solution of HNO_3 and H_2O_2 by wet digestion method, and the contents of trace elements, including B, Cu, K, Mg, Mn, Se, Zn, Cr, Fe and V in the sample solution, were determined by ICP-AES. The detection limits (3s) of the method were less than 0. 015 mg ·L~(-1).The values of recovery of trace elements found by standard addition method were ranged from 95. 4% to 106. 4%, with RSD's (n=6) of 2. 7%.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The sample of violet grown in Tianshan, was treated with a mixed solution of HNO_3 and H_2O_2 by wet digestion method, and the contents of trace elements, including B, Cu, K, Mg, Mn, Se, Zn, Cr, Fe and V in the sample solution, were determined by ICP-AES. The detection limits (3s) of the method were less than 0. 015 mg ·L~(-1).The values of recovery of trace elements found by standard addition method were ranged from 95. 4% to 106. 4%, with RSD's (n=6) of 2. 7%.

Key concepts: Inductively coupled plasma atomic emission spectroscopy, TRACE (psycholinguistics), Analytical Chemistry (journal), Standard addition, Chemistry, Detection limit, Standard solution, Nuclear chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
ICP-AES Determination of Trace Elements in Violet Grown in Tianshan — Research Paper | ScholarLens