2011•Xiandai huagongRequires access

Determination of Cr in soil by microwave digestion with inductively coupled plasma mass spectrometer

XU Chu-yang

Open publisher page 0 citations

Abstract

To establish a method for determine and analyze Cr in soil,the samples are digested by closed-vessel microwave and directly analyzed with ICP-MS.After microwave digestion in HNO3-HCl-HF mixed system,the samples are determined by ICP-MS.The internal standard elements In is used to compensate for matrix suppression effect and sensitivity drift.Meanwhile,the national standard reference material GBW07439 is determined and analyzed to verify the accuracy of this method.The results are shown as follows:less than 0.01 ng/g of the detection limits,over 0.9998 of the correlative coefficient of the calibration curves,lower than 2.5% of RSD,93.0%-105.3% of the recovery rates of Cr in certified reference material.This method is convenient,accurate and applied to determine various trace elements in soil samples.

About this research paper

What this paper is about

To establish a method for determine and analyze Cr in soil,the samples are digested by closed-vessel microwave and directly analyzed with ICP-MS.After microwave digestion in HNO3-HCl-HF mixed system,the samples are determined by ICP-MS.The internal standard elements In is used to compensate for matrix suppression effect and sensitivity drift.Meanwhile,the national standard reference material GBW07439 is determined and analyzed to verify the accuracy of this method.The results are shown as follows:less than 0.01 ng/g of the detection limits,over 0.9998 of the correlative coefficient of the calibration curves,lower than 2.5% of RSD,93.0%-105.3% of the recovery rates of Cr in certified reference material.This method is convenient,accurate and applied to determine various trace elements in soil samples.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To establish a method for determine and analyze Cr in soil,the samples are digested by closed-vessel microwave and directly analyzed with ICP-MS.After microwave digestion in HNO3-HCl-HF mixed system,the samples are determined by ICP-MS.The internal standard elements In is used to compensate for matrix suppression effect and sensitivity drift.Meanwhile,the national standard reference material GBW07439 is determined and analyzed to verify the accuracy of this method.The results are shown as follows:less than 0.01 ng/g of the detection limits,over 0.9998 of the correlative coefficient of the calibration curves,lower than 2.5% of RSD,93.0%-105.3% of the recovery rates of Cr in certified reference material.This method is convenient,accurate and applied to determine various trace elements in soil samples.

Key concepts: Microwave digestion, Analytical Chemistry (journal), Inductively coupled plasma mass spectrometry, Certified reference materials, Microwave, Calibration, Chemistry, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Cr in soil by microwave digestion with inductively coupled plasma mass spectrometer — Research Paper | ScholarLens