En-bloc repairing for blow-out fractures of orbital medial and inferior walls in 29 cases
Xiao-zhong Lu
Abstract
Xiao-zhong Lu
Abstract
Objective To investigate the surgical technique of en-bloc repairing for blow-out fractures of orbital medial and inferior walls.Design Retrospective case series.Participant 29 cases(29 eyes)with blow-out fractures of orbital medial and inferior walls.Method 29 cases of blow-out fracture of orbital medial and inferior walls were en-bloc repaired with HA.Exophthalmoses, dioplopia and the image of orbital CT scans were observed pre- and postoperatively.Main Outcome Measures Exophthalmoses, diplopia and orbital CT scans.Result Of all 29 cases,20 cases had satisfactory results in correction of endophthalmoses,while 9 cases had results of under-correction for 1 to 2mm.The symptom of dioplopia was not completely relieved in 4 cases only.Conclusion The en-bloc repairing for blow-out fractures of orbital medial and inferior walls is a new operative technique,with good results and few complications.(Ophthalmol CHN,2006,15:348-350)
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To investigate the surgical technique of en-bloc repairing for blow-out fractures of orbital medial and inferior walls.Design Retrospective case series.Participant 29 cases(29 eyes)with blow-out fractures of orbital medial and inferior walls.Method 29 cases of blow-out fracture of orbital medial and inferior walls were en-bloc repaired with HA.Exophthalmoses, dioplopia and the image of orbital CT scans were observed pre- and postoperatively.Main Outcome Measures Exophthalmoses, diplopia and orbital CT scans.Result Of all 29 cases,20 cases had satisfactory results in correction of endophthalmoses,while 9 cases had results of under-correction for 1 to 2mm.The symptom of dioplopia was not completely relieved in 4 cases only.Conclusion The en-bloc repairing for blow-out fractures of orbital medial and inferior walls is a new operative technique,with good results and few complications.(Ophthalmol CHN,2006,15:348-350)
Key concepts: Medicine, Diplopia, Orbital Fracture, Medial wall, Surgery, Computed tomography, Orbit (dynamics), Aerospace engineering