The value of X-ray and high-resolution computed tomography in the diagnosis of atypical foreign body in trachea and bronchus
Wang Bi
Abstract
Wang Bi
Abstract
Objective: To investigate the clinical value of chest fluoroscopy,chest radiography and high-resolution computed tomography(CT) in the diagnosis of atypical foreign body in trachea and bronchus. Methods: The data of chest fluoroscopy,chest radiography and high-resolution CT in 45 cases with atypical foreign body in trachea and bronchus diagnosed by fiberbronchoscopy were analyzed and compared. Results:The positive rate,false positive rate,false negative rate and misdiagnosis rate of chest fluoroscopy were52. 94%,17. 65%,11. 76% and 17. 65%,respectively. The positive rate,false positive rate,false negative rate and misdiagnosis rate of chest radiography were 53. 85%,15. 38%,15. 38% and 15. 38%,respectively. The positive rate of CT was 100. 00%,its false positive and negative rates were 0. 00% and 0. 00%,respectively. The difference of the positive rate in diagnosing the atypical foreign body in trachea and bronchus between chest fluoroscopy and chest radiography was not statistically significant( P 0. 05),but the diagnosic positive rate of high-resolation CT and reconstruction were higer than the fluoroscopy and radiography( P 0. 05). Conclusions:The sensibilities of chest fluoroscopy and radiography in diagnosing the atypical foreign body in trachea and bronchus are low,but CT detection is high. The CT detection is a reliable and noninvasive method for demonstrating the typical foreign body in trachea and bronchus.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To investigate the clinical value of chest fluoroscopy,chest radiography and high-resolution computed tomography(CT) in the diagnosis of atypical foreign body in trachea and bronchus. Methods: The data of chest fluoroscopy,chest radiography and high-resolution CT in 45 cases with atypical foreign body in trachea and bronchus diagnosed by fiberbronchoscopy were analyzed and compared. Results:The positive rate,false positive rate,false negative rate and misdiagnosis rate of chest fluoroscopy were52. 94%,17. 65%,11. 76% and 17. 65%,respectively. The positive rate,false positive rate,false negative rate and misdiagnosis rate of chest radiography were 53. 85%,15. 38%,15. 38% and 15. 38%,respectively. The positive rate of CT was 100. 00%,its false positive and negative rates were 0. 00% and 0. 00%,respectively. The difference of the positive rate in diagnosing the atypical foreign body in trachea and bronchus between chest fluoroscopy and chest radiography was not statistically significant( P 0. 05),but the diagnosic positive rate of high-resolation CT and reconstruction were higer than the fluoroscopy and radiography( P 0. 05). Conclusions:The sensibilities of chest fluoroscopy and radiography in diagnosing the atypical foreign body in trachea and bronchus are low,but CT detection is high. The CT detection is a reliable and noninvasive method for demonstrating the typical foreign body in trachea and bronchus.
Key concepts: Medicine, Fluoroscopy, Radiography, Radiology, Bronchus, Foreign body, False positive rate, Nuclear medicine