2002Progress in Microbiology and ImmunologyRequires access

Application and evaluation of recombinant HIV-I antigens

Ke Chen

Open publisher page 0 citations

Abstract

Microwell plates were pre coated with purified recombinant HIV 1 P24 and fusion P24 gp41 respectively. Serous samples from healthy donors and the national standard HIV Ab panel for HIV antibody tests were detected by ELISA with the pre coated plates. The results showed all of the healthy donors' sera were negative. For the national standard HIV Ab positive panel, the detective rate of the rP24 and the fussion P24 gp41 was 95%(19/20) and 90%(18/20) respectively. For the HIV Ab negative panel, the pass rate of the rP24 and the fusion P24 gp41 was 90%(18/20) and 60% (12/20) respectively,these result suggest that the developed rP24 has highly sensitivity and specificity and can be used in the manufacure of HIV antibody diagnositic reagent.

About this research paper

What this paper is about

Microwell plates were pre coated with purified recombinant HIV 1 P24 and fusion P24 gp41 respectively. Serous samples from healthy donors and the national standard HIV Ab panel for HIV antibody tests were detected by ELISA with the pre coated plates. The results showed all of the healthy donors' sera were negative. For the national standard HIV Ab positive panel, the detective rate of the rP24 and the fussion P24 gp41 was 95%(19/20) and 90%(18/20) respectively. For the HIV Ab negative panel, the pass rate of the rP24 and the fusion P24 gp41 was 90%(18/20) and 60% (12/20) respectively,these result suggest that the developed rP24 has highly sensitivity and specificity and can be used in the manufacure of HIV antibody diagnositic reagent.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Microwell plates were pre coated with purified recombinant HIV 1 P24 and fusion P24 gp41 respectively. Serous samples from healthy donors and the national standard HIV Ab panel for HIV antibody tests were detected by ELISA with the pre coated plates. The results showed all of the healthy donors' sera were negative. For the national standard HIV Ab positive panel, the detective rate of the rP24 and the fussion P24 gp41 was 95%(19/20) and 90%(18/20) respectively. For the HIV Ab negative panel, the pass rate of the rP24 and the fusion P24 gp41 was 90%(18/20) and 60% (12/20) respectively,these result suggest that the developed rP24 has highly sensitivity and specificity and can be used in the manufacure of HIV antibody diagnositic reagent.

Key concepts: Gp41, Human immunodeficiency virus (HIV), Recombinant DNA, Virology, Antibody, Antigen, Medicine, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Application and evaluation of recombinant HIV-I antigens — Research Paper | ScholarLens