2008•Liaoning Chemical IndustryRequires access

Simultaneous Determination of Co~(2+) and Ni~(2+) Content in Alloy Electrolyting Solution by Double-wavelength Spectrophotometric Method

Hong Wang

Open publisher page 0 citations

Abstract

The best experimentation condition to make a simultaneous determination of cobalt and nickel in alloy electrolyting solution by the dual-wavelength spectrophotometry with PAR as chromogenic regent was found out.In a solution of NH3·H2O–NH4Cl buffer at pH=8.0,the optimum spectrometric conditions of cobalt and nickel with PAR were studied by orthogonal design,and the result was satisfactory.The determination wavelength and reference wavelength were λmax,Co=512 nm,λCo=482 nm for cobalt and λmax,Ni=496 nm,λNi=526 nm for nickel.At these wavelength,the linear equation and linear range of y=0.0907x-0.0162 and 8.00~22.00 μg/25 mL of cobalt and the linear equation and linear range of y=0.3632x+0.0197and 4.00~14.00 μg/25 mL of nickel.Alloy electrolyting sample were determined by the proposed method.This method has been applied successfully to analyse alloy electrolyting solution.

About this research paper

What this paper is about

The best experimentation condition to make a simultaneous determination of cobalt and nickel in alloy electrolyting solution by the dual-wavelength spectrophotometry with PAR as chromogenic regent was found out.In a solution of NH3·H2O–NH4Cl buffer at pH=8.0,the optimum spectrometric conditions of cobalt and nickel with PAR were studied by orthogonal design,and the result was satisfactory.The determination wavelength and reference wavelength were λmax,Co=512 nm,λCo=482 nm for cobalt and λmax,Ni=496 nm,λNi=526 nm for nickel.At these wavelength,the linear equation and linear range of y=0.0907x-0.0162 and 8.00~22.00 μg/25 mL of cobalt and the linear equation and linear range of y=0.3632x+0.0197and 4.00~14.00 μg/25 mL of nickel.Alloy electrolyting sample were determined by the proposed method.This method has been applied successfully to analyse alloy electrolyting solution.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The best experimentation condition to make a simultaneous determination of cobalt and nickel in alloy electrolyting solution by the dual-wavelength spectrophotometry with PAR as chromogenic regent was found out.In a solution of NH3·H2O–NH4Cl buffer at pH=8.0,the optimum spectrometric conditions of cobalt and nickel with PAR were studied by orthogonal design,and the result was satisfactory.The determination wavelength and reference wavelength were λmax,Co=512 nm,λCo=482 nm for cobalt and λmax,Ni=496 nm,λNi=526 nm for nickel.At these wavelength,the linear equation and linear range of y=0.0907x-0.0162 and 8.00~22.00 μg/25 mL of cobalt and the linear equation and linear range of y=0.3632x+0.0197and 4.00~14.00 μg/25 mL of nickel.Alloy electrolyting sample were determined by the proposed method.This method has been applied successfully to analyse alloy electrolyting solution.

Key concepts: Cobalt, Nickel, Alloy, Wavelength, Chromogenic, Spectrophotometry, Analytical Chemistry (journal), Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous Determination of Co~(2+) and Ni~(2+) Content in Alloy Electrolyting Solution by Double-wavelength Spectrophotometric Method — Research Paper | ScholarLens