2013•Environmental Monitoring in ChinaRequires access

Quickly Determination of Pricia Acid in Water By High Performance Liquid Chromatography

Zou Ben-dong

Open publisher page 0 citations

Abstract

Pricia acid in water was determined by high performance liquid chromatography.The analytical conditions of HPLC were optimized though a series of tests.Results showed the optimum detected conditions were methanol-water(0.01%TFA) volume ratio of 45∶55 as the mobile phase and the temperature of 40 ℃.The detection wavelength was 350 nm for ultraviolet detector.Under the optimized conditions,limits of detection of this method was 0.4 μg/L.The recovery tests were analyzed using this new method: Three different grade include high、middle and low concentrations were added in surface and underground water samples separately,recoveries results of three concentrations were all above 88%,with relative standard deviations(RSD) blow 5%;And waste water recoveries were between 71% and 90%,with RSD was 7.9%.

About this research paper

What this paper is about

Pricia acid in water was determined by high performance liquid chromatography.The analytical conditions of HPLC were optimized though a series of tests.Results showed the optimum detected conditions were methanol-water(0.01%TFA) volume ratio of 45∶55 as the mobile phase and the temperature of 40 ℃.The detection wavelength was 350 nm for ultraviolet detector.Under the optimized conditions,limits of detection of this method was 0.4 μg/L.The recovery tests were analyzed using this new method: Three different grade include high、middle and low concentrations were added in surface and underground water samples separately,recoveries results of three concentrations were all above 88%,with relative standard deviations(RSD) blow 5%;And waste water recoveries were between 71% and 90%,with RSD was 7.9%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pricia acid in water was determined by high performance liquid chromatography.The analytical conditions of HPLC were optimized though a series of tests.Results showed the optimum detected conditions were methanol-water(0.01%TFA) volume ratio of 45∶55 as the mobile phase and the temperature of 40 ℃.The detection wavelength was 350 nm for ultraviolet detector.Under the optimized conditions,limits of detection of this method was 0.4 μg/L.The recovery tests were analyzed using this new method: Three different grade include high、middle and low concentrations were added in surface and underground water samples separately,recoveries results of three concentrations were all above 88%,with relative standard deviations(RSD) blow 5%;And waste water recoveries were between 71% and 90%,with RSD was 7.9%.

Key concepts: Chromatography, High-performance liquid chromatography, Chemistry, Detection limit, Volume (thermodynamics), Surface-area-to-volume ratio, Methanol, Ultraviolet