2011•Arid Environmental MonitoringRequires access

Determination of Atrazinein Surface Water and Drinking Water by HPLC

Wei Wu

Open publisher page 0 citations

Abstract

Taking ODS C18 as chromatographic column and methanol- water(60:40) as mobile phase, detection wavelength of 225 nm, column temperature 40 ℃ diehloromethane extracted, ration by external reference method, the HPLC method for determining atrazine in surface water and drinking water was established. Linear range was 0.02 ~ 10.0 mg/L and related coefficient was 0.999 9. The detection limit was 0.012 μg/L when sampling volume reached 500 ml. The results were satisfactory with the recoveries of 84.1% ~118% and the precision of 2.5% ~ 11.4%.

About this research paper

What this paper is about

Taking ODS C18 as chromatographic column and methanol- water(60:40) as mobile phase, detection wavelength of 225 nm, column temperature 40 ℃ diehloromethane extracted, ration by external reference method, the HPLC method for determining atrazine in surface water and drinking water was established. Linear range was 0.02 ~ 10.0 mg/L and related coefficient was 0.999 9. The detection limit was 0.012 μg/L when sampling volume reached 500 ml. The results were satisfactory with the recoveries of 84.1% ~118% and the precision of 2.5% ~ 11.4%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Taking ODS C18 as chromatographic column and methanol- water(60:40) as mobile phase, detection wavelength of 225 nm, column temperature 40 ℃ diehloromethane extracted, ration by external reference method, the HPLC method for determining atrazine in surface water and drinking water was established. Linear range was 0.02 ~ 10.0 mg/L and related coefficient was 0.999 9. The detection limit was 0.012 μg/L when sampling volume reached 500 ml. The results were satisfactory with the recoveries of 84.1% ~118% and the precision of 2.5% ~ 11.4%.

Key concepts: Atrazine, Chromatography, High-performance liquid chromatography, Surface water, Detection limit, Chemistry, Linear range, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Atrazinein Surface Water and Drinking Water by HPLC — Research Paper | ScholarLens