2008•Insulating MaterialsRequires access

Improvement of Lightning Withstand Level of 35 kV Transmission Lines by Using Line Arrester

Fan Zhang

Open publisher page 0 citations

Abstract

The joining of line arrester in insulator string in 35 kV transmission lines sections which are easily stroked by thunder was researched.The electromagnetic transient simulation calculation model of 35 kV transmission lines under the action of lightning wave was built.The influence of the line arrester on the lightning withstand level of 35 kV transmission lines was simulated and calculated by electromagnetic transient software ATP-EMTP.The results show that the joining of line arrester can obviously improve the lightning withstand level of 35 kV transmission lines,and is especially effective when the lightning directly strikes the conductor.When the lightning strikes the tower top,it is the tower grounding resistance that greatly affects the lightning withstand level.The lightning withstand level of 35 kV transmission lines under various joining plans of line arrester were simulated and calculated.

About this research paper

What this paper is about

The joining of line arrester in insulator string in 35 kV transmission lines sections which are easily stroked by thunder was researched.The electromagnetic transient simulation calculation model of 35 kV transmission lines under the action of lightning wave was built.The influence of the line arrester on the lightning withstand level of 35 kV transmission lines was simulated and calculated by electromagnetic transient software ATP-EMTP.The results show that the joining of line arrester can obviously improve the lightning withstand level of 35 kV transmission lines,and is especially effective when the lightning directly strikes the conductor.When the lightning strikes the tower top,it is the tower grounding resistance that greatly affects the lightning withstand level.The lightning withstand level of 35 kV transmission lines under various joining plans of line arrester were simulated and calculated.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The joining of line arrester in insulator string in 35 kV transmission lines sections which are easily stroked by thunder was researched.The electromagnetic transient simulation calculation model of 35 kV transmission lines under the action of lightning wave was built.The influence of the line arrester on the lightning withstand level of 35 kV transmission lines was simulated and calculated by electromagnetic transient software ATP-EMTP.The results show that the joining of line arrester can obviously improve the lightning withstand level of 35 kV transmission lines,and is especially effective when the lightning directly strikes the conductor.When the lightning strikes the tower top,it is the tower grounding resistance that greatly affects the lightning withstand level.The lightning withstand level of 35 kV transmission lines under various joining plans of line arrester were simulated and calculated.

Key concepts: Lightning arrester, Electric power transmission, Transmission line, Lightning (connector), Thunder, Insulator (electricity), Electrical engineering, Tower

Related papers

Back to paper searchBrowse research topicsOriginal source
Improvement of Lightning Withstand Level of 35 kV Transmission Lines by Using Line Arrester — Research Paper | ScholarLens