Determination of paeoniflorin and albiflorin in Radix paeoniae alba
Li-Na Ou
Abstract
Li-Na Ou
Abstract
Objective:To establish a high performance liquid chromatography method for the determination of paeoniflorin and albiflorin in Radix paeoniae alba.Methods:The HPLC method for determination of paeoniflorin and albiflorin was:Kromasil ODS2 column:(4.6mm×250mm,5μm),mobile phase:methanol-0.1% phosphate solution(adjusted to pH 4.2 with 1% sodium hydroxide)(34:66),flow rate:1.0 mL?min-1,detector wavelength:230 nm.Results:The linear range of paeoniflorin and albiflorin was 0.028~0.896μg(r =0.9999) and 0.0359~0.574μg(r = 0.9999),The average recovery was 98.18 % and 98.26% respectively,and both the RSD(n = 9) were less than 2%,The content determination of radix paeoniae alba of different producing areas and batches indicated that the content of paeoniflorin no less than 2.71%,albiflorin no less than 0.75%.Respectively,the average values was 2.93% and 0.95%.Conclusion:The method is sensitive,accurate,simple,and it can determine the paeoniflorin and albiflorin in radix paeoniae alba simultaneously.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To establish a high performance liquid chromatography method for the determination of paeoniflorin and albiflorin in Radix paeoniae alba.Methods:The HPLC method for determination of paeoniflorin and albiflorin was:Kromasil ODS2 column:(4.6mm×250mm,5μm),mobile phase:methanol-0.1% phosphate solution(adjusted to pH 4.2 with 1% sodium hydroxide)(34:66),flow rate:1.0 mL?min-1,detector wavelength:230 nm.Results:The linear range of paeoniflorin and albiflorin was 0.028~0.896μg(r =0.9999) and 0.0359~0.574μg(r = 0.9999),The average recovery was 98.18 % and 98.26% respectively,and both the RSD(n = 9) were less than 2%,The content determination of radix paeoniae alba of different producing areas and batches indicated that the content of paeoniflorin no less than 2.71%,albiflorin no less than 0.75%.Respectively,the average values was 2.93% and 0.95%.Conclusion:The method is sensitive,accurate,simple,and it can determine the paeoniflorin and albiflorin in radix paeoniae alba simultaneously.
Key concepts: Paeoniflorin, Chromatography, Chemistry, Paeonia lactiflora, High-performance liquid chromatography, Quantitative analysis (chemistry), Traditional medicine, Content determination