2014•Insulators and Surge ArrestersRequires access

Repeatability Study of Power Frequency Puncture Withstand Test for the Glass Insulator

Jia Min

Open publisher page 0 citations

Abstract

The repeatability and reproducibility of the power puncture withstand test for overhead line insulators is a puzzle of the insulator manufacturer and of the correlated independently test room all along. Taken the overhead line cap and pin glass insulator for example, based on the two research reports of CIGRE Task Force 33.07.01, and after testing once again, it is pointed out that, basic factors affecting the repeatability of the test are: resistivity, variety and dielectric strength of the test oil, and an operable mixture ratio of the test oil is proposed. And then repeatability verification test is carried out in a same test room, the aim is that hoping this study can provide experience to achieve the test reproducibility among the test rooms.

About this research paper

What this paper is about

The repeatability and reproducibility of the power puncture withstand test for overhead line insulators is a puzzle of the insulator manufacturer and of the correlated independently test room all along. Taken the overhead line cap and pin glass insulator for example, based on the two research reports of CIGRE Task Force 33.07.01, and after testing once again, it is pointed out that, basic factors affecting the repeatability of the test are: resistivity, variety and dielectric strength of the test oil, and an operable mixture ratio of the test oil is proposed. And then repeatability verification test is carried out in a same test room, the aim is that hoping this study can provide experience to achieve the test reproducibility among the test rooms.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The repeatability and reproducibility of the power puncture withstand test for overhead line insulators is a puzzle of the insulator manufacturer and of the correlated independently test room all along. Taken the overhead line cap and pin glass insulator for example, based on the two research reports of CIGRE Task Force 33.07.01, and after testing once again, it is pointed out that, basic factors affecting the repeatability of the test are: resistivity, variety and dielectric strength of the test oil, and an operable mixture ratio of the test oil is proposed. And then repeatability verification test is carried out in a same test room, the aim is that hoping this study can provide experience to achieve the test reproducibility among the test rooms.

Key concepts: Repeatability, Reproducibility, Insulator (electricity), Test method, Materials science, Test equipment, Dielectric, Overhead (engineering)

Related papers

Back to paper searchBrowse research topicsOriginal source
Repeatability Study of Power Frequency Puncture Withstand Test for the Glass Insulator — Research Paper | ScholarLens